Tip
Need help? Please let us know in the UMEP Community.
Please report issues with the manual on the GitHub Issues.
Please cite SUEWS with proper information from our Zenodo page.
2.5.2.1. CBLinput¶
-
EntrainmentType
¶
-
- Requirement
-
Required
- Description
-
Determines entrainment scheme. See Cleugh and Grimmond 2000 [16] for details.
- Configuration
-
Value
Comments
1
Tennekes and Driedonks (1981) - Recommended in this version.
2
McNaughton and Springs (1986)
3
Rayner and Watson (1991)
4
Tennekes (1973)
-
QH_Choice
¶
-
- Requirement
-
Required
- Description
-
Determines QH used for CBL model.
- Configuration
-
Value
Comments
1
QH modelled by SUEWS
2
QH modelled by LUMPS
3
Observed QH values are used from the meteorological input file
-
InitialData_use
¶
-
- Requirement
-
Required
- Description
-
Determines initial values (see CBL_initial_data.txt)
- Configuration
-
Value
Comments
0
All initial values are calculated. Not available in this version.
1
Take zi0, gamt_Km and gamq_gkgm from input data file. Theta+_K, q+_gkg, Theta_K and q_gkg are calculated using Temp_C, avrh and Pres_kPa in meteorological input file.
2
Take all initial values from input data file (see CBL_Initial_data.txt).
-
Sondeflag
¶
-
- Requirement
-
Required
- Description
-
to fill
- Configuration
-
Value
Comments
0
Does not read radiosonde vertical profile data - Recommended in this version.
1
Reads radiosonde vertical profile data
-
CBLday(id)
¶
-
- Requirement
-
Required
- Description
-
Set CBLday(id) = 1 If CBL model is set to run for DOY 175–177, CBLday(175) = 1, CBLday(176) = 1, CBLday(177) = 1
- Configuration
-
to fill
-
CO2_included
¶
-
- Requirement
-
Required
- Description
-
Set to zero in current version
- Configuration
-
to fill
-
FileSonde(id)
¶
-
- Requirement
-
Required
- Description
-
If Sondeflag=1, write the file name including the path from site directory e.g. FileSonde(id)= ‘CBLinputfilesXXX.txt’, XXX is an arbitrary name.
- Configuration
-
to fill
-
InitialDataFileName
¶
-
- Requirement
-
Required
- Description
-
If InitialData_use ≥ 1, write the file name including the path from site directory e.g. InitialDataFileName=’CBLinputfilesCBL_initial_data.txt’
- Configuration
-
to fill
-
Wsb
¶
-
- Requirement
-
Required
- Description
-
Subsidence velocity (m s-1 ) in eq. 1 and 2 of Onomura et al. (2015) [17] . (-0.01 m s-1 Recommended in this version.)
- Configuration
-
to fill