Tip
Need help? Please let us know in the UMEP Community.
Please report issues with the manual on the GitHub Issues.
Please cite SUEWS with proper information from our Zenodo page.
3.6.2.1. ESTMinput#
- TsurfChoice#
- Requirement:
Required
- Description:
Source of surface temperature data used.
- Configuration:
Value
Comments
0
Tsurf
in SSss_YYYY_ESTM_Ts_data_tt.txt used for all surface elements.1
Input surface temperature are different for ground, roof and wall.
2
Wall surface temperature is different for four directions.
- evolveTibld#
- Requirement:
Required
- Description:
Source of internal building temperature (Tibld)
- Configuration:
Value
Comments
0
Tiair
in SSss_YYYY_ESTM_Ts_data_tt.txt used.1
Tibld calculated considering the effect of anthropogenic heat from HVAC
2
Tibld calculated without considering the influence of HVAC.
- IbldCHmod#
- Requirement:
Required
- Description:
Method to calculate internal convective heat exchange coefficients (CH) for internal building, wall and roof if evolveTibld is 1 or 2.
- Configuration:
Value
Comments
0
CHs are read from SUEWS_ESTMcoefficients.txt.
1
CHs are calculated based on ASHRAE (2001)
2
CHs are calculated based on Awbi (1998).
- LBC_soil#
- Requirement:
Required
- Description:
Soil temperature at lowest boundary condition [ËšC]
- Configuration:
to fill
- Theat_fix#
- Requirement:
Required
- Description:
Ideal internal building temperature [ËšC]
- Configuration:
to fill
- Theat_off#
- Requirement:
Required
- Description:
Temperature at which heat control is turned off (used when evolveTibld=1) [ËšC]
- Configuration:
to fill
- Theat_on#
- Requirement:
Required
- Description:
Temperature at which heat control is turned on (used when evolveTibld =1) [ËšC]
- Configuration:
to fill