ESTMinput

Tip

  1. Need help? Please let us know in the UMEP Community.

  2. Please report issues with the manual on the GitHub Issues.

  3. Please cite SUEWS with proper information from our Zenodo page.

3.6.2.1. ESTMinput#

TsurfChoice#
Requirement

Required

Description

Source of surface temperature data used.

Configuration

Value

Comments

0

Tsurf in SSss_YYYY_ESTM_Ts_data_tt.txt used for all surface elements.

1

Input surface temperature are different for ground, roof and wall.

2

Wall surface temperature is different for four directions.

evolveTibld#
Requirement

Required

Description

Source of internal building temperature (Tibld)

Configuration

Value

Comments

0

Tiair in SSss_YYYY_ESTM_Ts_data_tt.txt used.

1

Tibld calculated considering the effect of anthropogenic heat from HVAC

2

Tibld calculated without considering the influence of HVAC.

IbldCHmod#
Requirement

Required

Description

Method to calculate internal convective heat exchange coefficients (CH) for internal building, wall and roof if evolveTibld is 1 or 2.

Configuration

Value

Comments

0

CHs are read from SUEWS_ESTMcoefficients.txt.

1

CHs are calculated based on ASHRAE (2001)

2

CHs are calculated based on Awbi (1998).

LBC_soil#
Requirement

Required

Description

Soil temperature at lowest boundary condition [ËšC]

Configuration

to fill

Theat_fix#
Requirement

Required

Description

Ideal internal building temperature [ËšC]

Configuration

to fill

Theat_off#
Requirement

Required

Description

Temperature at which heat control is turned off (used when evolveTibld=1) [ËšC]

Configuration

to fill

Theat_on#
Requirement

Required

Description

Temperature at which heat control is turned on (used when evolveTibld =1) [ËšC]

Configuration

to fill