a1
¶
-
- Description
-
Coefficient for Q* term [-]
- Configuration
-
Referencing Table
Requirement
Comment
Coefficient for Q* term [-]
-
a2
¶
-
- Description
-
Coefficient for
dQ*/dt
term [h] - Configuration
-
Referencing Table
Requirement
Comment
Coefficient for dQ*/dt term [h]
-
a3
¶
-
- Description
-
Constant term [W m-2]
- Configuration
-
Referencing Table
Requirement
Comment
Constant term [W m-2]
-
ActivityProfWD
¶
-
- Description
-
Code linking to
ActivityProfWD
in SUEWS_Profiles.txt. - Configuration
-
Referencing Table
Requirement
Comment
Code for human activity profile (weekdays) Provides the link to column 1 of SUEWS_Profiles.txt. Value of integer is arbitrary but must match code specified in column 1 of SUEWS_Profiles.txt. Used for CO2 flux calculation.
-
ActivityProfWE
¶
-
- Description
-
Code linking to
ActivityProfWE
in SUEWS_Profiles.txt. - Configuration
-
Referencing Table
Requirement
Comment
Code for human activity profile (weekends) Provides the link to column 1 of SUEWS_Profiles.txt. Look the codes Value of integer is arbitrary but must match code specified in column 1 of SUEWS_Profiles.txt. Used for CO2 flux calculation.
-
AHMin_WD
¶
-
- Description
-
Minimum QF on weekdays [W m-2]
- Configuration
-
Referencing Table
Requirement
Comment
Use with
EmissionsMethod
= 1
-
AHMin_WE
¶
-
- Description
-
Minimum QF on weekends [W m-2]
- Configuration
-
Referencing Table
Requirement
Comment
Use with
EmissionsMethod
= 1
-
AHSlope_Heating_WD
¶
-
- Description
-
Heating slope of QF on weekdays [W m-2 K-1]
- Configuration
-
Referencing Table
Requirement
Comment
Use with
EmissionsMethod
= 1
-
AHSlope_Heating_WE
¶
-
- Description
-
Heating slope of QF on weekends [W m-2 K-1]
- Configuration
-
Referencing Table
Requirement
Comment
Use with
EmissionsMethod
= 1
-
AHSlope_Cooling_WD
¶
-
- Description
-
Cooling slope of QF on weekdays [W m-2 K-1]
- Configuration
-
Referencing Table
Requirement
Comment
Use with
EmissionsMethod
= 1
-
AHSlope_Cooling_WE
¶
-
- Description
-
Cooling slope of QF on weekends [W m-2 K-1]
- Configuration
-
Referencing Table
Requirement
Comment
Use with
EmissionsMethod
= 1
-
AlbedoMax
¶
-
- Description
-
Effective surface albedo (middle of the day value) for summertime.
- Configuration
-
Referencing Table
Requirement
Comment
Effective surface albedo (middle of the day value) for summertime. View factors should be taken into account.
Example values [-]
Example values [-]
0.1 Water (Oke, 2002)
Example values [-]
0.85 (Järvi et al., 2014)
-
AlbedoMin
¶
-
- Description
-
Effective surface albedo (middle of the day value) for wintertime (not including snow).
- Configuration
-
Referencing Table
Requirement
Comment
Not currently used for non-vegetated surfaces – set the same as AlbedoMax.
Example values [-]
Not currently used for water surface - set same as AlbedoMax.
Example values [-]
0.18 (Järvi et al., 2014)
-
alpha
¶
-
- Description
-
The mean apparent ecosystem quantum. Represents the initial slope of the light-response curve. [umol CO2 umol photons^-1]
- Configuration
-
Referencing Table
Requirement
Comment
Example values:
EmissionsMethod
= 11, 12, 13, 14, 15 or 16:0.044 (Ruimy et al., 1995)
0.0593 (Schmid, 2000)
0.0205 (Flanagan et al., 2002)
EmissionsMethod
= 21, 22, 23, 24, 25, or 26: 0.031 (Bellucco et al., 2017)EmissionsMethod
= 31, 32, 33, 34, 35, 36: 0.005 (Bellucco et al., 2017)
-
Alt
¶
-
- Description
-
Altitude of grids [m].
- Configuration
-
Referencing Table
Requirement
Comment
Used for both the radiation and water flow between grids. Not available in this version.
-
AnOHM_Ch
¶
-
- Description
-
Bulk transfer coefficient for this surface to use in AnOHM [-]
- Configuration
-
Referencing Table
Requirement
Comment
Bulk transfer coefficient for this surface to use in AnOHM [-]
Bulk transfer coefficient for this surface to use in AnOHM [-]
Bulk transfer coefficient for this surface to use in AnOHM [-]
Bulk transfer coefficient for this surface to use in AnOHM [-]
-
AnOHM_Cp
¶
-
- Description
-
Volumetric heat capacity for this surface to use in AnOHM [J m-3]
- Configuration
-
Referencing Table
Requirement
Comment
Volumetric heat capacity for this surface to use in AnOHM [J m-3]
Volumetric heat capacity for this surface to use in AnOHM [J m-3]
Volumetric heat capacity for this surface to use in AnOHM [J m-3]
Volumetric heat capacity for this surface to use in AnOHM [J m-3]
-
AnOHM_Kk
¶
-
- Description
-
Thermal conductivity for this surface to use in AnOHM [W m K-1]
- Configuration
-
Referencing Table
Requirement
Comment
Thermal conductivity for this surface to use in AnOHM [W m K-1]
Thermal conductivity for this surface to use in AnOHM [W m K-1]
Thermal conductivity for this surface to use in AnOHM [W m K-1]
Thermal conductivity for this surface to use in AnOHM [W m K-1]
-
AnthropogenicCode
¶
-
- Description
-
Code for modelling anthropogenic heat flux linking to
Code
of SUEWS_AnthropogenicEmission.txt, which contains the model coefficients for estimation of the anthropogenic heat flux (used ifEmissionsMethod
= 1, 2 in RunControl.nml). - Configuration
-
Referencing Table
Requirement
Comment
Value of integer is arbitrary but must match code specified in column 1 of SUEWS_AnthropogenicEmission.txt.
-
AreaWall
¶
-
- Description
-
Area of wall within grid (needed for ESTM calculation) [ m2 ].
- Configuration
-
Referencing Table
Requirement
Comment
Area of wall within grid (needed for ESTM calculation). [ m2 ]
-
BaseT
¶
-
- Description
-
Base Temperature for initiating growing degree days (GDD) for leaf growth. [°C]
- Configuration
-
Referencing Table
Requirement
Comment
See section 2.2 Järvi et al. (2011); Appendix A of Järvi et al. (2014). Example values: 5 for EveTr (Järvi et al., 2011)
-
BaseTe
¶
-
BaseT_HC
¶
-
- Description
-
Base temperature for heating degree days [°C]
- Configuration
-
Referencing Table
Requirement
Comment
Base temperature for heating degree days [°C] e.g. Sailor and Vasireddy (2006)
-
beta
¶
-
- Description
-
The light-saturated gross photosynthesis of the canopy. [umol m-2 s-1 ]
- Configuration
-
Referencing Table
Requirement
Comment
Example values:
EmissionsMethod
= 11, 12, 13, 14, 15, 16:43.35 (Ruimy et al., 1995)
35 (Schmid, 2000)
16.3 (Flanagan et al., 2002)
EmissionsMethod
= 21, 22, 23, 24, 25, 26: 17.793 (Bellucco et al., 2017)EmissionsMethod
= 31, 32, 33, 34, 35, 36: 8.474 (Bellucco et al., 2017)
-
theta
¶
-
- Description
-
The convexity of the curve at light saturation.
- Configuration
-
Referencing Table
Requirement
Comment
Example value:
EmissionsMethod
= 21, 22, 23, 24, 25, 26: 0.723 (Bellucco et al., 2017)EmissionsMethod
= 31, 32, 33, 34, 35, 36: 0.96 (Bellucco et al., 2017)
-
alpha_enh
¶
-
- Description
-
Part of the
alpha
coefficient related to the fraction of vegetation. - Configuration
-
Referencing Table
Requirement
Comment
Example value: 0.016 (Bellucco et al., 2017)
-
beta_enh
¶
-
- Description
-
Part of the
beta
coefficient related to the fraction of vegetation. - Configuration
-
Referencing Table
Requirement
Comment
Example values: 33.454 (Bellucco et al., 2017)
-
resp_a
¶
-
- Description
-
Respiration coefficient a.
- Configuration
-
Referencing Table
Requirement
Comment
Example values:
1.08 (Schmid, 2000)
3.229 (Järvi et al., 2012)
-
resp_b
¶
-
- Description
-
Respiration coefficient b - related to air temperature dependency.
- Configuration
-
Referencing Table
Requirement
Comment
Example values:
0.0064 (Schmid, 2000)
0.0329 (Järvi et al., 2012)
-
min_respi
¶
-
- Description
-
Minimum soil respiration rate (for cold-temperature limit) [umol m-2 s-1].
- Configuration
-
Referencing Table
Requirement
Comment
Example values: 0.6 estimate from Hyytiälä forest site.
-
BiogenCO2Code
¶
-
- Description
-
Code linking to the
Code
column in SUEWS_BiogenCO2.txt. - Configuration
-
Referencing Table
Requirement
Comment
Code linking to the
Code
column in SUEWS_BiogenCO2.txt.
-
QF0_BEU_WD
¶
-
- Description
-
Building energy use [W m-2]
- Configuration
-
Referencing Table
Requirement
Comment
Weekday building energy use [W m-2] Can be used for CO2 flux calculation.
-
QF0_BEU_WE
¶
-
- Description
-
Building energy use [W m-2]
- Configuration
-
Referencing Table
Requirement
Comment
Can be used for CO2 flux calculation.
-
CO2PointSource
¶
-
- Description
-
CO2 emission factor [kg km-1]
- Configuration
-
Referencing Table
Requirement
Comment
CO2 emission factor [kg km-1]
-
Code
¶
-
- Description
-
Code linking to a corresponding look-up table.
- Configuration
-
Referencing Table
Requirement
Comment
Code linking to SUEWS_SiteSelect.txt for paved surfaces (Code_Paved), buildings (Code_Bldgs) and bare soil surfaces (Code_BSoil). Value of integer is arbitrary but must match codes specified in SUEWS_SiteSelect.txt.
Code linking to SUEWS_SiteSelect.txt for evergreen trees and shrubs (Code_EveTr), deciduous trees and shrubs (Code_DecTr) and grass surfaces (Code_Grass). Value of integer is arbitrary but must match codes specified in SUEWS_SiteSelect.txt.
Code linking to SUEWS_SiteSelect.txt for water surfaces (Code_Water). Value of integer is arbitrary but must match code specified in SUEWS_SiteSelect.txt.
Code linking to SUEWS_SiteSelect.txt for snow surfaces (SnowCode). Value of integer is arbitrary but must match code specified in SUEWS_SiteSelect.txt.
Code linking to the SoilTypeCode column in SUEWS_NonVeg.txt (for Paved, Bldgs and BSoil surfaces) and SUEWS_Veg.txt (for EveTr, DecTr and Grass surfaces). Value of integer is arbitrary but must match code specified in SUEWS_SiteSelect.txt.
Code linking to the CondCode column in SUEWS_SiteSelect.txt . Value of integer is arbitrary but must match code specified in SUEWS_SiteSelect.txt.
Code linking to the AnthropogenicCode column in SUEWS_SiteSelect.txt . Value of integer is arbitrary but must match code specified in SUEWS_SiteSelect.txt.
Code linking to SUEWS_SiteSelect.txt for irrigation modelling (IrrigationCode). Value of integer is arbitrary but must match codes specified in SUEWS_SiteSelect.txt.
Code linking to the
OHMCode_SummerWet
,OHMCode_SummerDry
,OHMCode_WinterWet
andOHMCode_WinterDry
columns in SUEWS_NonVeg.txt, SUEWS_Veg.txt, SUEWS_Water.txt and SUEWS_Snow.txt files. Value of integer is arbitrary but must match code specified in SUEWS_SiteSelect.txt.For buildings and paved surfaces, set to zero if there is more than one ESTM class per grid and the codes and surface fractions specified in SUEWS_SiteSelect.txt will be used instead.
Code linking to the
BiogenCO2Code
column in SUEWS_Veg.txt.
-
Code_Bldgs
¶
-
- Description
-
Code for
Bldgs
surface characteristics linking toCode
of SUEWS_NonVeg.txt - Configuration
-
Referencing Table
Requirement
Comment
Code for Bldgs surface characteristics Provides the link to column 1 of SUEWS_NonVeg.txt, which contains the attributes describing buildings in this grid for this year. Value of integer is arbitrary but must match code specified in column 1 of SUEWS_NonVeg.txt.
-
Code_BSoil
¶
-
- Description
-
Code for
BSoil
surface characteristics linking toCode
of SUEWS_NonVeg.txt - Configuration
-
Referencing Table
Requirement
Comment
Value of integer is arbitrary but must match code specified in column 1 of SUEWS_NonVeg.txt.
-
Code_DecTr
¶
-
- Description
-
Code for
DecTr
surface characteristics linking toCode
of SUEWS_Veg.txt - Configuration
-
Referencing Table
Requirement
Comment
Code for DecTr surface characteristics Provides the link to column 1 of SUEWS_Veg.txt, which contains the attributes describing deciduous trees and shrubs in this grid for this year. Value of integer is arbitrary but must match code specified in column 1 of SUEWS_Veg.txt.
-
Code_ESTMClass_Bldgs1
¶
-
- Description
-
Code linking to SUEWS_ESTMCoefficients.txt
- Configuration
-
Referencing Table
Requirement
Comment
Code linking to SUEWS_ESTMCoefficients.txt
-
Code_ESTMClass_Bldgs2
¶
-
- Description
-
Code linking to SUEWS_ESTMCoefficients.txt
- Configuration
-
Referencing Table
Requirement
Comment
Code linking to SUEWS_ESTMCoefficients.txt
-
Code_ESTMClass_Bldgs3
¶
-
- Description
-
Code linking to SUEWS_ESTMCoefficients.txt
- Configuration
-
Referencing Table
Requirement
Comment
Code linking to SUEWS_ESTMCoefficients.txt
-
Code_ESTMClass_Bldgs4
¶
-
- Description
-
Code linking to SUEWS_ESTMCoefficients.txt
- Configuration
-
Referencing Table
Requirement
Comment
Code linking to SUEWS_ESTMCoefficients.txt
-
Code_ESTMClass_Bldgs5
¶
-
- Description
-
Code linking to SUEWS_ESTMCoefficients.txt
- Configuration
-
Referencing Table
Requirement
Comment
Code linking to SUEWS_ESTMCoefficients.txt
-
Code_ESTMClass_Paved1
¶
-
- Description
-
Code linking to SUEWS_ESTMCoefficients.txt
- Configuration
-
Referencing Table
Requirement
Comment
Code linking to SUEWS_ESTMCoefficients.txt
-
Code_ESTMClass_Paved2
¶
-
- Description
-
Code linking to SUEWS_ESTMCoefficients.txt
- Configuration
-
Referencing Table
Requirement
Comment
Code linking to SUEWS_ESTMCoefficients.txt
-
Code_ESTMClass_Paved3
¶
-
- Description
-
Code linking to SUEWS_ESTMCoefficients.txt
- Configuration
-
Referencing Table
Requirement
Comment
Code linking to SUEWS_ESTMCoefficients.txt
-
Code_EveTr
¶
-
- Description
-
Code for
EveTr
surface characteristics linking toCode
of SUEWS_Veg.txt - Configuration
-
Referencing Table
Requirement
Comment
Code for EveTr surface characteristics Provides the link to column 1 of SUEWS_Veg.txt, which contains the attributes describing evergreen trees and shrubs in this grid for this year. Value of integer is arbitrary but must match code specified in column 1 of SUEWS_Veg.txt.
-
Code_Grass
¶
-
- Description
-
Code for
Grass
surface characteristics linking toCode
of SUEWS_Veg.txt - Configuration
-
Referencing Table
Requirement
Comment
Code for Grass surface characteristics Provides the link to column 1 of SUEWS_Veg.txt, which contains the attributes describing grass surfaces in this grid for this year. Value of integer is arbitrary but must match code specified in column 1 of SUEWS_Veg.txt.
-
Code_Paved
¶
-
- Description
-
Code for
Paved
surface characteristics linking toCode
of SUEWS_NonVeg.txt - Configuration
-
Referencing Table
Requirement
Comment
Code for Paved surface characteristics Provides the link to column 1 of SUEWS_NonVeg.txt, which contains the attributes describing paved areas in this grid for this year. Value of integer is arbitrary but must match code specified in column 1 of SUEWS_NonVeg.txt. e.g. 331 means use the characteristics specified in the row of input file SUEWS_NonVeg.txt which has 331 in column 1 (Code).
-
Code_Water
¶
-
- Description
-
Code for
Water
surface characteristics linking toCode
of SUEWS_Water.txt - Configuration
-
Referencing Table
Requirement
Comment
Code for Water surface characteristics Provides the link to column 1 of SUEWS_Water.txt, which contains the attributes describing open water in this grid for this year. Value of integer is arbitrary but must match code specified in column 1 of SUEWS_Water.txt.
-
CondCode
¶
-
- Description
-
Code for surface conductance parameters linking to
Code
of SUEWS_Conductance.txt - Configuration
-
Referencing Table
Requirement
Comment
Code for surface conductance parameters Provides the link to column 1 of SUEWS_Conductance.txt, which contains the parameters for the Jarvis (1976) parameterisation of surface conductance. Value of integer is arbitrary but must match code specified in column 1 of SUEWS_Conductance.txt. e.g. 33 means use the characteristics specified in the row of input file SUEWS_Conductance.txt which has 33 in column 1 (Code).
-
CRWMax
¶
-
- Description
-
Maximum water holding capacity of snow [mm]
- Configuration
-
Referencing Table
Requirement
Comment
Maximum water holding capacity of snow [mm]
-
CRWMin
¶
-
- Description
-
Minimum water holding capacity of snow [mm]
- Configuration
-
Referencing Table
Requirement
Comment
Minimum water holding capacity of snow [mm]
-
DayWat(1)
¶
-
- Description
-
Irrigation allowed on Sundays [1], if not [0]
- Configuration
-
Referencing Table
Requirement
Comment
Irrigation allowed on Sundays [1], if not [0]
-
DayWat(2)
¶
-
- Description
-
Irrigation allowed on Mondays [1], if not [0]
- Configuration
-
Referencing Table
Requirement
Comment
Irrigation allowed on Mondays [1], if not [0]
-
DayWat(3)
¶
-
- Description
-
Irrigation allowed on Tuesdays [1], if not [0]
- Configuration
-
Referencing Table
Requirement
Comment
Irrigation allowed on Tuesdays [1], if not [0]
-
DayWat(4)
¶
-
- Description
-
Irrigation allowed on Wednesdays [1], if not [0]
- Configuration
-
Referencing Table
Requirement
Comment
Irrigation allowed on Wednesdays [1], if not [0]
-
DayWat(5)
¶
-
- Description
-
Irrigation allowed on Thursdays [1], if not [0]
- Configuration
-
Referencing Table
Requirement
Comment
Irrigation allowed on Thursdays [1], if not [0]
-
DayWat(6)
¶
-
- Description
-
Irrigation allowed on Fridays [1], if not [0]
- Configuration
-
Referencing Table
Requirement
Comment
Irrigation allowed on Fridays [1], if not [0]
-
DayWat(7)
¶
-
- Description
-
Irrigation allowed on Saturdays [1], if not [0]
- Configuration
-
Referencing Table
Requirement
Comment
Irrigation allowed on Saturdays [1], if not [0]
-
DayWatPer(1)
¶
-
- Description
-
Fraction of properties using irrigation on Sundays [0-1]
- Configuration
-
Referencing Table
Requirement
Comment
Fraction of properties using irrigation on Sundays [0-1]
-
DayWatPer(2)
¶
-
- Description
-
Fraction of properties using irrigation on Mondays [0-1]
- Configuration
-
Referencing Table
Requirement
Comment
Fraction of properties using irrigation on Mondays [0-1]
-
DayWatPer(3)
¶
-
- Description
-
Fraction of properties using irrigation on Tuesdays [0-1]
- Configuration
-
Referencing Table
Requirement
Comment
Fraction of properties using irrigation on Tuesdays [0-1]
-
DayWatPer(4)
¶
-
- Description
-
Fraction of properties using irrigation on Wednesdays [0-1]
- Configuration
-
Referencing Table
Requirement
Comment
Fraction of properties using irrigation on Wednesdays [0-1]
-
DayWatPer(5)
¶
-
- Description
-
Fraction of properties using irrigation on Thursdays [0-1]
- Configuration
-
Referencing Table
Requirement
Comment
Fraction of properties using irrigation on Thursdays [0-1]
-
DayWatPer(6)
¶
-
- Description
-
Fraction of properties using irrigation on Fridays [0-1]
- Configuration
-
Referencing Table
Requirement
Comment
Fraction of properties using irrigation on Fridays [0-1]
-
DayWatPer(7)
¶
-
- Description
-
Fraction of properties using irrigation on Saturdays [0-1]
- Configuration
-
Referencing Table
Requirement
Comment
Fraction of properties using irrigation on Saturdays [0-1]
-
DrainageCoef1
¶
-
- Description
-
Coefficient D0 [mm h-1] used in
DrainageEq
- Configuration
-
Referencing Table
Requirement
Comment
-
Example values:
DrainageEq
= 3, 10 forPaved
andBldgs
;DrainageEq
= 2, 0.013 forBSoil
-
Example values:
DrainageEq
= 3, 10 forGrass
(irrigated);DrainageEq
= 2, 0.013 forEveTr
,DecTr
,Grass
(unirrigated)
Not currently used for water surface
-
-
DrainageCoef2
¶
-
- Description
-
Coefficient b [-] used in
DrainageEq
- Configuration
-
Referencing Table
Requirement
Comment
-
Example values:
DrainageEq
= 3, 3 forPaved
andBldgs
DrainageEq
= 2, 1.71 forBSoil
-
Example values:
DrainageEq
= 3, 3 forGrass
(irrigated)DrainageEq
= 2, 1.71 forEveTr
,DecTr
,Grass
(unirrigated)
Not currently used for water surface
-
-
DrainageEq
¶
-
- Description
-
Calculation choice for Drainage equation
- Configuration
-
Referencing Table
Requirement
Comment
-
Options:
1: Falk and Niemczynowicz (1978)
2: Halldin et al. (1979) (Rutter eqn corrected for c=0, see Calder & Wright (1986) (Calder and Wright, 1986) )
3: for
EveTr
,DecTr
,Grass
(unirrigated) see Falk and Niemczynowicz (1978). Coefficients are specified in the following two columns. Recommended in this version.
Not currently used for water surface.
-
-
EF_umolCO2perJ
¶
-
- Description
-
Emission factor for fuels used for building heating.
- Configuration
-
Referencing Table
Requirement
Comment
Weekday building energy use [W m-2] Can be used for CO2 flux calculation.
-
Emissivity
¶
-
- Description
-
Effective surface emissivity.
- Configuration
-
Referencing Table
Requirement
Comment
Effective surface emissivity. View factors should be taken into account.
Example values [-]
Example values [-]
0.95 Water (Oke, 2002)
Example values [-]
0.99 (Järvi et al., 2014)
-
EndDLS
¶
-
- Description
-
End of the day light savings [DOY]
- Configuration
-
Referencing Table
Requirement
Comment
End of the day light savings [DOY] See Day Light Savings (DLS).
-
EnEF_v_Jkm
¶
-
- Description
-
Emission factor for heat [J k m-1 ].
- Configuration
-
Referencing Table
Requirement
Comment
Emission factor for heat [J k m-1]. Example values: 3.97e6 Sailor and Lu (2004) (Sailor and Lu, 2004)
-
EnergyUseProfWD
¶
-
- Description
-
Code linking to
EnergyUseProfWD
in SUEWS_Profiles.txt. - Configuration
-
Referencing Table
Requirement
Comment
Code for energy use profile (weekdays) Provides the link to column 1 of SUEWS_Profiles.txt. Look the codes Value of integer is arbitrary but must match code specified in column 1 of SUEWS_Profiles.txt.
-
EnergyUseProfWE
¶
-
- Description
-
Code linking to
EnergyUseProfWE
in SUEWS_Profiles.txt. - Configuration
-
Referencing Table
Requirement
Comment
Code for energy use profile (weekends) Provides the link to column 1 of SUEWS_Profiles.txt. Value of integer is arbitrary but must match code specified in column 1 of SUEWS_Profiles.txt.
-
ESTMCode
¶
-
- Description
-
Code for ESTM coefficients linking to SUEWS_ESTMCoefficients.txt
- Configuration
-
Referencing Table
Requirement
Comment
For paved and building surfaces, it is possible to specify multiple codes per grid (3 for paved, 5 for buildings) using SUEWS_SiteSelect.txt . In this case, set ESTMCode here to zero.
Code for ESTM coefficients to use for this surface. Links to SUEWS_ESTMCoefficients.txt . Value of integer is arbitrary but must match code specified in column 1 of SUEWS_ESTMCoefficients.txt.
Code for ESTM coefficients to use for this surface. Links to SUEWS_ESTMCoefficients.txt . Value of integer is arbitrary but must match code specified in column 1 of SUEWS_ESTMCoefficients.txt.
For paved and building surfaces, it is possible to specify multiple codes per grid (3 for paved, 5 for buildings) using SUEWS_SiteSelect.txt . In this case, set ESTM code here to zero.
-
FAI_Bldgs
¶
-
- Description
-
Frontal area index for buildings [-]
- Configuration
-
Referencing Table
Requirement
Comment
Frontal area index for buildings [-] Required if
RoughLenMomMethod
= 3 in RunControl.nml .
-
FAI_DecTr
¶
-
- Description
-
Frontal area index for deciduous trees [-]
- Configuration
-
Referencing Table
Requirement
Comment
Frontal area index for deciduous trees [-] Required if
RoughLenMomMethod
= 3 in RunControl.nml .
-
FAI_EveTr
¶
-
- Description
-
Frontal area index for evergreen trees [-]
- Configuration
-
Referencing Table
Requirement
Comment
Frontal area index for evergreen trees [-] Required if
RoughLenMomMethod
= 3 in RunControl.nml .
-
Faut
¶
-
- Description
-
Fraction of irrigated area that is irrigated using automated systems
- Configuration
-
Referencing Table
Requirement
Comment
Fraction of irrigated area that is irrigated using automated systems (e.g. sprinklers).
-
FcEF_v_kgkmWD
¶
-
- Description
-
CO2 emission factor for weekdays [kg km-1]
- Configuration
-
Referencing Table
Requirement
Comment
CO2 emission factor for weekdays [kg km-1] Can be used for CO2 flux calculation.
-
FcEF_v_kgkmWE
¶
-
- Description
-
CO2 emission factor for weekends [kg km-1]
- Configuration
-
Referencing Table
Requirement
Comment
CO2 emission factor for weekdays [kg km-1] Can be used for CO2 flux calculation.
-
FcEF_v_Jkm
¶
-
- Description
-
Traffic emission factor for CO2.
- Configuration
-
Referencing Table
Requirement
Comment
Weekday building energy use [W m-2] Can be used for CO2 flux calculation.
-
fcld
¶
-
- Description
-
Cloud fraction [tenths]
- Configuration
-
Referencing Table
Requirement
Comment
Cloud fraction [tenths]
-
FlowChange
¶
-
- Description
-
Difference in input and output flows for water surface [mm h-1]
- Configuration
-
Referencing Table
Requirement
Comment
Difference in input and output flows for water surface [mm h-1] Used to indicate river or stream flow through the grid. Currently not fully tested!
-
Fraction1of8
¶
-
- Description
-
Fraction of water that can flow to
GridConnection1of8
[-] - Configuration
-
Referencing Table
Requirement
Comment
Fraction of water that can flow to the grid specified in previous column [-]
-
Fraction2of8
¶
-
- Description
-
Fraction of water that can flow to
GridConnection2of8
[-] - Configuration
-
Referencing Table
Requirement
Comment
Fraction of water that can flow to the grid specified in previous column [-]
-
Fraction3of8
¶
-
- Description
-
Fraction of water that can flow to
GridConnection3of8
[-] - Configuration
-
Referencing Table
Requirement
Comment
Fraction of water that can flow to the grid specified in previous column [-]
-
Fraction4of8
¶
-
- Description
-
Fraction of water that can flow to
GridConnection4of8
[-] - Configuration
-
Referencing Table
Requirement
Comment
Fraction of water that can flow to the grid specified in previous column [-]
-
Fraction5of8
¶
-
- Description
-
Fraction of water that can flow to
GridConnection5of8
[-] - Configuration
-
Referencing Table
Requirement
Comment
Fraction of water that can flow to the grid specified in previous column [-]
-
Fraction6of8
¶
-
- Description
-
Fraction of water that can flow to
GridConnection6of8
[-] - Configuration
-
Referencing Table
Requirement
Comment
Fraction of water that can flow to the grid specified in previous column [-]
-
Fraction7of8
¶
-
- Description
-
Fraction of water that can flow to
GridConnection7of8
[-] - Configuration
-
Referencing Table
Requirement
Comment
Fraction of water that can flow to the grid specified in previous column [-]
-
Fraction8of8
¶
-
- Description
-
Fraction of water that can flow to
GridConnection8of8
[-] - Configuration
-
Referencing Table
Requirement
Comment
Fraction of water that can flow to the grid specified in previous column [-]
-
Fr_Bldgs
¶
-
- Description
-
Surface cover fraction of buildings [-]
- Configuration
-
Referencing Table
Requirement
Comment
Surface cover fraction of buildings [-]
-
Fr_Bsoil
¶
-
- Description
-
Surface cover fraction of bare soil or unmanaged land [-]
- Configuration
-
Referencing Table
Requirement
Comment
Surface cover fraction of bare soil or unmanaged land [-]
-
Fr_DecTr
¶
-
- Description
-
Surface cover fraction of deciduous trees and shrubs [-]
- Configuration
-
Referencing Table
Requirement
Comment
Surface cover fraction of deciduous trees and shrubs [-]
-
Fr_ESTMClass_Bldgs1
¶
-
- Description
-
Surface cover fraction of building class 1 used in ESTM calculations
- Configuration
-
Referencing Table
Requirement
Comment
Columns 94-98 must add up to 1
-
Fr_ESTMClass_Bldgs2
¶
-
- Description
-
Surface cover fraction of building class 2 used in ESTM calculations
- Configuration
-
Referencing Table
Requirement
Comment
Columns 94-98 must add up to 1
-
Fr_ESTMClass_Bldgs3
¶
-
- Description
-
Surface cover fraction of building class 3 used in ESTM calculations
- Configuration
-
Referencing Table
Requirement
Comment
Columns 94-98 must add up to 1
-
Fr_ESTMClass_Bldgs4
¶
-
- Description
-
Surface cover fraction of building class 4 used in ESTM calculations
- Configuration
-
Referencing Table
Requirement
Comment
Columns 94-98 must add up to 1
-
Fr_ESTMClass_Bldgs5
¶
-
- Description
-
Surface cover fraction of building class 5 used in ESTM calculations
- Configuration
-
Referencing Table
Requirement
Comment
Columns 94-98 must add up to 1
-
Fr_ESTMClass_Paved1
¶
-
- Description
-
Surface cover fraction of
Paved
surface class 1 used in ESTM calculations - Configuration
-
Referencing Table
Requirement
Comment
Columns 88-90 must add up to 1
-
Fr_ESTMClass_Paved2
¶
-
- Description
-
Surface cover fraction of
Paved
surface class 2 used in ESTM calculations - Configuration
-
Referencing Table
Requirement
Comment
Columns 88-90 must add up to 1
-
Fr_ESTMClass_Paved3
¶
-
- Description
-
Surface cover fraction of
Paved
surface class 3 used in ESTM calculations - Configuration
-
Referencing Table
Requirement
Comment
Columns 88-90 must add up to 1
-
Fr_EveTr
¶
-
- Description
-
Surface cover fraction of
EveTr
: evergreen trees and shrubs [-] - Configuration
-
Referencing Table
Requirement
Comment
Surface cover fraction of evergreen trees and shrubs [-]
-
Fr_Grass
¶
-
- Description
-
Surface cover fraction of
Grass
[-] - Configuration
-
Referencing Table
Requirement
Comment
Surface cover fraction of grass [-]
-
Fr_Paved
¶
-
- Description
-
Surface cover fraction of
Paved
surfaces [-] - Configuration
-
Referencing Table
Requirement
Comment
Columns 14 to 20 must sum to 1 .
-
Fr_Water
¶
-
- Description
-
Surface cover fraction of open water [-]
- Configuration
-
Referencing Table
Requirement
Comment
Surface cover fraction of open water [-] (e.g. river, lakes, ponds, swimming pools)
-
FrFossilFuel_Heat
¶
-
- Description
-
Fraction of fossil fuels used for building heating [-]
- Configuration
-
Referencing Table
Requirement
Comment
Weekday building energy use [W m-2] Can be used for CO2 flux calculation.
-
FrFossilFuel_NonHeat
¶
-
- Description
-
Fraction of fossil fuels used for building energy use [-]
- Configuration
-
Referencing Table
Requirement
Comment
Weekday building energy use [W m-2] Can be used for CO2 flux calculation.
-
FrPDDwe
¶
-
- Description
-
Fraction of weekend population to weekday population. [-]
- Configuration
-
Referencing Table
Requirement
Comment
Fraction of weekend population to weekday population. [-]
-
G1
¶
-
- Description
-
Related to maximum surface conductance [mm s-1]
- Configuration
-
Referencing Table
Requirement
Comment
Related to maximum surface conductance [mm s-1]
-
G2
¶
-
- Description
-
Related to Kdown dependence [W m-2]
- Configuration
-
Referencing Table
Requirement
Comment
Related to Kdown dependence [W m-2]
-
G3
¶
-
- Description
-
Related to VPD dependence [units depend on
gsModel
] - Configuration
-
Referencing Table
Requirement
Comment
Related to VPD dependence [units depend on gsChoice in RunControl.nml ]
-
G4
¶
-
- Description
-
Related to VPD dependence [units depend on
gsModel
] - Configuration
-
Referencing Table
Requirement
Comment
Related to VPD dependence [units depend on gsChoice in RunControl.nml ]
-
G5
¶
-
- Description
-
Related to temperature dependence [°C]
- Configuration
-
Referencing Table
Requirement
Comment
Related to temperature dependence [°C]
-
G6
¶
-
- Description
-
Related to soil moisture dependence [mm-1]
- Configuration
-
Referencing Table
Requirement
Comment
Related to soil moisture dependence [mm-1]
-
gamq_gkgm
¶
-
- Description
-
vertical gradient of specific humidity [g kg-1 m-1]
- Configuration
-
Referencing Table
Requirement
Comment
vertical gradient of specific humidity (g kg-1 m-1 )
-
gamt_Km
¶
-
- Description
-
vertical gradient of potential temperature [K m-1]
- Configuration
-
Referencing Table
Requirement
Comment
vertical gradient of potential temperature (K m-1 ) strength of the inversion
-
GDDFull
¶
-
- Description
-
The growing degree days (GDD) needed for full capacity of the leaf area index (LAI) [°C].
- Configuration
-
Referencing Table
Requirement
Comment
This should be checked carefully for your study area using modelled LAI from the DailyState output file compared to known behaviour in the study area. See section 2.2 Järvi et al. (2011) ; Appendix A Järvi et al. (2014) for more details. Example values: 300 for
EveTr
Järvi et al. (2011)
-
Grid
¶
-
- Description
-
a unique number to represent grid
- Configuration
-
Referencing Table
Requirement
Comment
Grid numbers do not need to be consecutive and do not need to start at a particular value. Each grid must have a unique grid number. All grids must be present for all years. These grid numbers are referred to in GridConnections (columns 64-79) ( N.B. Not available in this version. )
-
GridConnection1of8
¶
-
- Description
-
Number of the 1st grid where water can flow to The next 8 pairs of columns specify the water flow between grids. The first column of each pair specifies the grid that the water flows to (from the current grid, column 1); the second column of each pair specifies the fraction of water that flow to that grid. The fraction (i.e. amount) of water transferred may be estimated based on elevation, the length of connecting surface between grids, presence of walls, etc. Water cannot flow from the current grid to the same grid, so the grid number here must be different to the grid number in column 1. Water can flow to a maximum of 8 other grids. If there is no water flow between grids, or a single grid is run, set to 0. See section on Grid Connections
- Configuration
-
Referencing Table
Requirement
Comment
The next 8 pairs of columns specify the water flow between grids. The first column of each pair specifies the grid that the water flows to (from the current grid, column 1); the second column of each pair specifies the fraction of water that flow to that grid. The fraction (i.e. amount) of water transferred may be estimated based on elevation, the length of connecting surface between grids, presence of walls, etc. Water cannot flow from the current grid to the same grid, so the grid number here must be different to the grid number in column 1. Water can flow to a maximum of 8 other grids. If there is no water flow between grids, or a single grid is run, set to 0. See section on Grid Connections
-
GridConnection2of8
¶
-
- Description
-
Number of the 2nd grid where water can flow to
- Configuration
-
Referencing Table
Requirement
Comment
Number of the grid where water can flow to
-
GridConnection3of8
¶
-
- Description
-
Number of the 3rd grid where water can flow to
- Configuration
-
Referencing Table
Requirement
Comment
Number of the grid where water can flow to
-
GridConnection4of8
¶
-
- Description
-
Number of the 4th grid where water can flow to
- Configuration
-
Referencing Table
Requirement
Comment
Number of the grid where water can flow to
-
GridConnection5of8
¶
-
- Description
-
Number of the 5th grid where water can flow to
- Configuration
-
Referencing Table
Requirement
Comment
Number of the grid where water can flow to
-
GridConnection6of8
¶
-
- Description
-
Number of the 6th grid where water can flow to
- Configuration
-
Referencing Table
Requirement
Comment
Number of the grid where water can flow to
-
GridConnection7of8
¶
-
- Description
-
Number of the 7th grid where water can flow to
- Configuration
-
Referencing Table
Requirement
Comment
Number of the grid where water can flow to
-
GridConnection8of8
¶
-
- Description
-
Number of the 8th grid where water can flow to
- Configuration
-
Referencing Table
Requirement
Comment
Number of the grid where water can flow to
-
gsModel
¶
-
- Description
-
Formulation choice for conductance calculation.
- Configuration
-
Referencing Table
Requirement
Comment
2
(Ward et al., 2016) Recommended in this version.
-
H_Bldgs
¶
-
- Description
-
Mean building height [m]
- Configuration
-
Referencing Table
Requirement
Comment
Mean building height [m]
-
H_DecTr
¶
-
- Description
-
Mean height of deciduous trees [m]
- Configuration
-
Referencing Table
Requirement
Comment
Mean height of deciduous trees [m]
-
H_EveTr
¶
-
- Description
-
Mean height of evergreen trees [m]
- Configuration
-
Referencing Table
Requirement
Comment
Mean height of evergreen trees [m]
-
H_maintain
¶
-
- Description
-
water depth to maintain used in automatic irrigation (e.g., ponding water due to flooding irrigation in rice crop-field) [mm].
Note
H_maintain
can be positive (e.g., ponding water due to flooding irrigation in rice crop-field) or negative (e.g., soil water store level to maintain:SoilStoreCap
+H_maintain
) or zero (e.g., to maintain a maximum soil store level, i.e.,SoilStoreCap
).Disable this feature by setting this parameter to
-999
: then no restrictions will be applied to maintain available water level.
- Configuration
-
Referencing Table
Requirement
Comment
water depth to maintain used in automatic irrigation.
-
id
¶
-
- Description
-
Day of year [DOY]
- Configuration
-
Referencing Table
Requirement
Comment
Not used: set to 1 in this version.
Day of year [DOY]
Day of year [DOY]
Day of year [DOY]
-
Ie_a1
¶
-
- Description
-
Coefficient for automatic irrigation model [mm d-1 ]
- Configuration
-
Referencing Table
Requirement
Comment
Coefficient for automatic irrigation model [mm d -1 ]
-
Ie_a2
¶
-
- Description
-
Coefficient for automatic irrigation model [mm d-1 K-1]
- Configuration
-
Referencing Table
Requirement
Comment
Coefficient for automatic irrigation model [mm d -1 K-1]
-
Ie_a3
¶
-
- Description
-
Coefficient for automatic irrigation model [mm d-2 ]
- Configuration
-
Referencing Table
Requirement
Comment
Coefficient for automatic irrigation model [mm d -2 ]
-
Ie_end
¶
-
- Description
-
Day when irrigation ends [DOY]
- Configuration
-
Referencing Table
Requirement
Comment
Day when irrigation ends [DOY]
-
Ie_m1
¶
-
- Description
-
Coefficient for manual irrigation model [mm d-1 ]
- Configuration
-
Referencing Table
Requirement
Comment
Coefficient for manual irrigation model [mm d -1 ]
-
Ie_m2
¶
-
- Description
-
Coefficient for manual irrigation model [mm d-1 K-1]
- Configuration
-
Referencing Table
Requirement
Comment
Coefficient for manual irrigation model [mm d -1 K-1]
-
Ie_m3
¶
-
- Description
-
Coefficient for manual irrigation model [mm d-2 ]
- Configuration
-
Referencing Table
Requirement
Comment
Coefficient for manual irrigation model [mm d -2 ]
-
Ie_start
¶
-
- Description
-
Day when irrigation starts [DOY]
- Configuration
-
Referencing Table
Requirement
Comment
Day when irrigation starts [DOY]
-
ih
¶
-
- Description
-
Hour [H]
- Configuration
-
Referencing Table
Requirement
Comment
Hour [H] Not used: set to 0 in this version.
-
imin
¶
-
- Description
-
Minute [M]
- Configuration
-
Referencing Table
Requirement
Comment
Minute [M] Not used: set to 0 in this version.
Minute [M]
Minute [M]
-
InfiltrationRate
¶
-
- Description
-
Infiltration rate.
- Configuration
-
Referencing Table
Requirement
Comment
Not currently used
-
Internal_albedo
¶
-
- Description
-
Albedo of all internal elements for building surfaces only
- Configuration
-
Referencing Table
Requirement
Comment
Albedo of all internal elements for building surfaces only
-
Internal_CHbld
¶
-
- Description
-
Bulk transfer coefficient of internal building elements [W m-2 K-1]
- Configuration
-
Referencing Table
Requirement
Comment
Bulk transfer coefficient of internal building elements [W m-2 K-1] (for building surfaces only and if
IbldCHmod
== 0 in ESTMinput.nml
-
Internal_CHroof
¶
-
- Description
-
Bulk transfer coefficient of internal roof [W m-2 K-1]
- Configuration
-
Referencing Table
Requirement
Comment
Bulk transfer coefficient of internal roof [W m-2 K-1] (for building surfaces only and if
IbldCHmod
== 0 in ESTMinput.nml
-
Internal_CHwall
¶
-
- Description
-
Bulk transfer coefficient of internal wall [W m-2 K-1]
- Configuration
-
Referencing Table
Requirement
Comment
Bulk transfer coefficient of internal wall [W m-2 K-1] (for building surfaces only and if
IbldCHmod
== 0 in ESTMinput.nml
-
Internal_emissivity
¶
-
- Description
-
Emissivity of all internal elements for building surfaces only
- Configuration
-
Referencing Table
Requirement
Comment
Emissivity of all internal elements for building surfaces only
-
Internal_k1
¶
-
- Description
-
Thermal conductivity of the first layer [W m-1 K-1]
- Configuration
-
Referencing Table
Requirement
Comment
Thermal conductivity of the first layer [W m-1 K-1]
-
Internal_k2
¶
-
- Description
-
Thermal conductivity of the second layer [W m-1 K-1]
- Configuration
-
Referencing Table
Requirement
Comment
Thermal conductivity of the second layer [W m-1 K-1]
-
Internal_k3
¶
-
- Description
-
Thermal conductivity of the third layer [W m-1 K-1]
- Configuration
-
Referencing Table
Requirement
Comment
Thermal conductivity of the third layer [W m-1 K-1]
-
Internal_k4
¶
-
- Description
-
Thermal conductivity of the fourth layer [W m-1 K-1]
- Configuration
-
Referencing Table
Requirement
Comment
Thermal conductivity of the fourth layer [W m-1 K-1]
-
Internal_k5
¶
-
- Description
-
Thermal conductivity of the fifth layer [W m-1 K-1]
- Configuration
-
Referencing Table
Requirement
Comment
Thermal conductivity of the fifth layer [W m-1 K-1]
-
Internal_rhoCp1
¶
-
- Description
-
Volumetric heat capacity of the first layer[J m-3 K-1]
- Configuration
-
Referencing Table
Requirement
Comment
Volumetric heat capacity of the first layer[J m-3 K-1]
-
Internal_rhoCp2
¶
-
- Description
-
Volumetric heat capacity of the second layer [J m-3 K-1]
- Configuration
-
Referencing Table
Requirement
Comment
Volumetric heat capacity of the second layer [J m-3 K-1]
-
Internal_rhoCp3
¶
-
- Description
-
Volumetric heat capacity of the third layer[J m-3 K-1]
- Configuration
-
Referencing Table
Requirement
Comment
Volumetric heat capacity of the third layer[J m-3 K-1]
-
Internal_rhoCp4
¶
-
- Description
-
Volumetric heat capacity of the fourth layer [J m-3 K-1]
- Configuration
-
Referencing Table
Requirement
Comment
Volumetric heat capacity of the fourth layer [J m-3 K-1]
-
Internal_rhoCp5
¶
-
- Description
-
Volumetric heat capacity of the fifth layer [J m-3 K-1]
- Configuration
-
Referencing Table
Requirement
Comment
Volumetric heat capacity of the fifth layer [J m-3 K-1]
-
Internal_thick1
¶
-
- Description
-
Thickness of the first layer [m] for building surfaces only
- Configuration
-
Referencing Table
Requirement
Comment
Thickness of the first layer [m] for building surfaces only; set to -999 for all other surfaces
-
Internal_thick2
¶
-
- Description
-
Thickness of the second layer [m]
- Configuration
-
Referencing Table
Requirement
Comment
Thickness of the second layer [m] (if no second layer, set to -999.)
-
Internal_thick3
¶
-
- Description
-
Thickness of the third layer [m]
- Configuration
-
Referencing Table
Requirement
Comment
Thickness of the third layer [m] (if no third layer, set to -999.)
-
Internal_thick4
¶
-
- Description
-
Thickness of the fourth layer [m]
- Configuration
-
Referencing Table
Requirement
Comment
Thickness of the fourth layer [m] (if no fourth layer, set to -999.)
-
Internal_thick5
¶
-
- Description
-
Thickness of the fifth layer [m]
- Configuration
-
Referencing Table
Requirement
Comment
Thickness of the fifth layer [m] (if no fifth layer, set to -999.)
-
InternalWaterUse
¶
-
- Description
-
Internal water use [mm h-1]
- Configuration
-
Referencing Table
Requirement
Comment
Internal water use [mm h-1]
-
IrrFr_Paved
¶
-
- Description
-
Fraction of
Paved
that is irrigated [-] - Configuration
-
Referencing Table
Requirement
Comment
Fraction of paved surfaces that are irrigated [-]
-
IrrFr_Bldgs
¶
-
- Description
-
Fraction of
Bldgs
that is irrigated [-] - Configuration
-
Referencing Table
Requirement
Comment
Fraction of rooftop of buildings (e.g., green roofs) that are irrigated [-]
-
IrrFr_DecTr
¶
-
- Description
-
Fraction of
DecTr
that is irrigated [-] - Configuration
-
Referencing Table
Requirement
Comment
Fraction of deciduous trees that are irrigated [-]
-
IrrFr_EveTr
¶
-
- Description
-
Fraction of
EveTr
that is irrigated [-] - Configuration
-
Referencing Table
Requirement
Comment
Fraction of evergreen trees that are irrigated [-] e.g. 50% of the evergreen trees/shrubs are irrigated
-
IrrFr_Grass
¶
-
- Description
-
Fraction of
Grass
that is irrigated [-] - Configuration
-
Referencing Table
Requirement
Comment
Fraction of grass that is irrigated [-]
-
IrrFr_BSoil
¶
-
- Description
-
Fraction of
BSoil
that is irrigated [-] - Configuration
-
Referencing Table
Requirement
Comment
Fraction of bare soil that are irrigated [-]
-
IrrFr_Water
¶
-
- Description
-
Fraction of
Water
that is irrigated [-] - Configuration
-
Referencing Table
Requirement
Comment
Fraction of water that are irrigated [-]
-
IrrigationCode
¶
-
- Description
-
Code for modelling irrigation linking to
Code
of SUEWS_Irrigation.txt - Configuration
-
Referencing Table
Requirement
Comment
Code for modelling irrigation Provides the link to column 1 of SUEWS_Irrigation.txt, which contains the model coefficients for estimation of the water use (used if WU_Choice = 0 in RunControl.nml ). Value of integer is arbitrary but must match code specified in column 1 of SUEWS_Irrigation.txt.
-
it
¶
-
- Description
-
Hour [H]
- Configuration
-
Referencing Table
Requirement
Comment
Hour [H]
Hour [H]
-
iy
¶
-
- Description
-
Year [YYYY]
- Configuration
-
Referencing Table
Requirement
Comment
Year [YYYY]
Year [YYYY]
-
kdiff
¶
-
- Description
-
Diffuse radiation [W m-2].
- Configuration
-
Referencing Table
Requirement
Comment
Recommended if SOLWEIGUse = 1
-
kdir
¶
-
- Description
-
Direct radiation [W m-2].
- Configuration
-
Referencing Table
Requirement
Comment
Recommended if SOLWEIGUse = 1
-
kdown
¶
-
- Description
-
Incoming shortwave radiation [W m-2].
- Configuration
-
Referencing Table
Requirement
Comment
Must be > 0 W m-2 .
-
Kmax
¶
-
- Description
-
Maximum incoming shortwave radiation [W m-2]
- Configuration
-
Referencing Table
Requirement
Comment
Maximum incoming shortwave radiation [W m-2]
-
lai
¶
-
- Description
-
Observed leaf area index [m-2 m-2]
- Configuration
-
Referencing Table
Requirement
Comment
Observed leaf area index [m-2 m-2]
-
LAIEq
¶
-
- Description
-
LAI calculation choice.
Note
North and South hemispheres are treated slightly differently.
- Configuration
-
Referencing Table
Requirement
Comment
Coefficients are specified in the following parameters:
LeafGrowthPower1
,LeafGrowthPower2
,LeafOffPower1
andLeafOffPower2
.Options
-
LAIMax
¶
-
- Description
-
full leaf-on summertime value
- Configuration
-
Referencing Table
Requirement
Comment
full leaf-on summertime value Example values: - 5.1 EveTr Breuer et al. (2003) (Breuer et al., 2003) - 5.5 DecTr Breuer et al. (2003) (Breuer et al., 2003) - 5.9 Grass Breuer et al. (2003) (Breuer et al., 2003)
-
LAIMin
¶
-
- Description
-
leaf-off wintertime value
- Configuration
-
Referencing Table
Requirement
Comment
leaf-off wintertime value Example values: - 4. EveTr (Järvi et al., 2011) - 1. DecTr (Järvi et al., 2011) - 1.6 Grass (Grimmond and Oke, 1991)
-
lat
¶
-
- Description
-
Latitude [deg].
- Configuration
-
Referencing Table
Requirement
Comment
Use coordinate system WGS84. Positive values are northern hemisphere (negative southern hemisphere). Used in radiation calculations. Note, if the total modelled area is small the latitude and longitude could be the same for each grid but small differences in radiation will not be determined. If you are defining the latitude and longitude differently between grids make certain that you provide enough decimal places.
-
ldown
¶
-
- Description
-
Incoming longwave radiation [W m-2]
- Configuration
-
Referencing Table
Requirement
Comment
Incoming longwave radiation [W m-2]
-
LeafGrowthPower1
¶
-
- Description
-
a parameter required by LAI calculation in
LAIEq
- Configuration
-
Referencing Table
Requirement
Comment
Example values
LAIEq
= 0: 0.03 (Järvi et al., 2011)LAIEq
= 1: 0.04 (Järvi et al., 2014)
-
LeafGrowthPower2
¶
-
- Description
-
a parameter required by LAI calculation [K-1] in
LAIEq
- Configuration
-
Referencing Table
Requirement
Comment
Example values
LAIEq
= 0: 0.0005 (Järvi et al., 2011)LAIEq
= 1: 0.001 (Järvi et al., 2014)
-
LeafOffPower1
¶
-
- Description
-
a parameter required by LAI calculation [K-1] in
LAIEq
- Configuration
-
Referencing Table
Requirement
Comment
Example values
LAIEq
= 0: 0.03 (Järvi et al., 2011)LAIEq
= 1: -1.5 (Järvi et al., 2014)
-
LeafOffPower2
¶
-
- Description
-
a parameter required by LAI calculation [K-1] in
LAIEq
- Configuration
-
Referencing Table
Requirement
Comment
Example values
LAIEq
= 0: 0.0005 (Järvi et al., 2011)LAIEq
= 1: 0.0015 (Järvi et al., 2014)
-
lng
¶
-
- Description
-
longitude [deg]
- Configuration
-
Referencing Table
Requirement
Comment
Use coordinate system WGS84. For compatibility with GIS, negative values are to the west, positive values are to the east (e.g. Vancouver = -123.12; Shanghai = 121.47) Note this is a change of sign convention between v2016a and v2017a See latitude for more details.
-
LUMPS_Cover
¶
-
- Description
-
Limit when surface totally covered with water for LUMPS [mm]
- Configuration
-
Referencing Table
Requirement
Comment
Limit when surface totally covered with water [mm] Used for LUMPS surface wetness control. Default recommended value of 1 mm from Loridan et al. (2011) .
-
LUMPS_DrRate
¶
-
- Description
-
Drainage rate of bucket for LUMPS [mm h-1]
- Configuration
-
Referencing Table
Requirement
Comment
Drainage rate of bucket for LUMPS [mm h-1] Used for LUMPS surface wetness control. Default recommended value of 0.25 mm h-1 from Loridan et al. (2011) .
-
LUMPS_MaxRes
¶
-
- Description
-
Maximum water bucket reservoir [mm] Used for LUMPS surface wetness control.
- Configuration
-
Referencing Table
Requirement
Comment
Maximum water bucket reservoir [mm] Used for LUMPS surface wetness control. Default recommended value of 10 mm from Loridan et al. (2011) .
-
MaxQFMetab
¶
-
- Description
-
Maximum value for human heat emission. [W m-2]
Example values: 175 Sailor and Lu (2004) (Sailor and Lu, 2004)
- Configuration
-
Referencing Table
Requirement
Comment
Maximum value for human heat emission. [W m-2]
-
MaxFCMetab
¶
-
- Description
-
Maximum (day) CO2 from human metabolism. [W m-2]
- Configuration
-
Referencing Table
Requirement
Comment
Maximum (day) CO2 from human metabolism. [W m-2]
-
MaxConductance
¶
-
- Description
-
The maximum conductance of each vegetation or surface type. [mm s-1]
- Configuration
-
Referencing Table
Requirement
Comment
Example values [mm s-1]
7.4: EveTr (Järvi et al., 2011)
11.7: DecTr (Järvi et al., 2011)
33.1: Grass (unirrigated) (Järvi et al., 2011)
40.: Grass (irrigated) (Järvi et al., 2011)
-
MinQFMetab
¶
-
- Description
-
Minimum value for human heat emission. [W m-2]
Example values: 75 Sailor and Lu (2004) (Sailor and Lu, 2004)
- Configuration
-
Referencing Table
Requirement
Comment
Minimum value for human heat emission. [W m-2].
-
MinFCMetab
¶
-
- Description
-
Minimum (night) CO2 from human metabolism. [W m-2]
- Configuration
-
Referencing Table
Requirement
Comment
Minimum (night) CO2 from human metabolism. [W m-2]
-
NARP_Trans
¶
-
- Description
-
Atmospheric transmissivity for NARP [-]
- Configuration
-
Referencing Table
Requirement
Comment
Atmospheric transmissivity for NARP [-] Value must in the range 0-1. Default recommended value of 1.
-
nroom
¶
-
- Description
-
Number of rooms per floor for building surfaces only [-]
- Configuration
-
Referencing Table
Requirement
Comment
Number of rooms per floor for building surfaces only
-
OBS_SMCap
¶
-
- Description
-
The maximum observed soil moisture. [m3 m-3 or kg kg-1]
- Configuration
-
Referencing Table
Requirement
Comment
Use only if soil moisture is observed and provided in the met forcing file and
SMDMethod
= 1 or 2. Use of observed soil moisture not currently tested
-
OBS_SMDepth
¶
-
- Description
-
The depth of soil moisture measurements. [mm]
- Configuration
-
Referencing Table
Requirement
Comment
Use only if soil moisture is observed and provided in the met forcing file and
SMDMethod
= 1 or 2. Use of observed soil moisture not currently tested
-
OBS_SoilNotRocks
¶
-
- Description
-
Fraction of soil without rocks. [-]
- Configuration
-
Referencing Table
Requirement
Comment
Use only if soil moisture is observed and provided in the met forcing file and
SMDMethod
= 1 or 2. Use of observed soil moisture not currently tested
-
OHMCode_SummerDry
¶
-
- Description
-
Code for OHM coefficients to use for this surface during dry conditions in summer, linking to SUEWS_OHMCoefficients.txt.
- Configuration
-
Referencing Table
Requirement
Comment
Code for OHM coefficients to use for this surface during dry conditions in summer. Links to SUEWS_OHMCoefficients.txt . Value of integer is arbitrary but must match code specified in column 1 of SUEWS_OHMCoefficients.txt.
Code for OHM coefficients to use for this surface during dry conditions in summer. Links to SUEWS_OHMCoefficients.txt . Value of integer is arbitrary but must match code specified in column 1 of SUEWS_OHMCoefficients.txt.
Code for OHM coefficients to use for this surface during dry conditions in summer. Links to SUEWS_OHMCoefficients.txt . Value of integer is arbitrary but must match code specified in column 1 of SUEWS_OHMCoefficients.txt.
Code for OHM coefficients to use for this surface during dry conditions in summer. Links to SUEWS_OHMCoefficients.txt . Value of integer is arbitrary but must match code specified in column 1 of SUEWS_OHMCoefficients.txt.
-
OHMCode_SummerWet
¶
-
- Description
-
Code for OHM coefficients to use for this surface during wet conditions in summer, linking to SUEWS_OHMCoefficients.txt.
- Configuration
-
Referencing Table
Requirement
Comment
Code for OHM coefficients to use for this surface during wet conditions in summer. Links to SUEWS_OHMCoefficients.txt . Value of integer is arbitrary but must match code specified in column 1 of SUEWS_OHMCoefficients.txt.
Code for OHM coefficients to use for this surface during wet conditions in summer. Links to SUEWS_OHMCoefficients.txt . Value of integer is arbitrary but must match code specified in column 1 of SUEWS_OHMCoefficients.txt.
Code for OHM coefficients to use for this surface during wet conditions in summer. Links to SUEWS_OHMCoefficients.txt . Value of integer is arbitrary but must match code specified in column 1 of SUEWS_OHMCoefficients.txt.
Code for OHM coefficients to use for this surface during wet conditions in summer. Links to SUEWS_OHMCoefficients.txt . Value of integer is arbitrary but must match code specified in column 1 of SUEWS_OHMCoefficients.txt.
-
OHMCode_WinterDry
¶
-
- Description
-
Code for OHM coefficients to use for this surface during dry conditions in winter, linking to SUEWS_OHMCoefficients.txt.
- Configuration
-
Referencing Table
Requirement
Comment
Code for OHM coefficients to use for this surface during dry conditions in winter. Links to SUEWS_OHMCoefficients.txt . Value of integer is arbitrary but must match code specified in column 1 of SUEWS_OHMCoefficients.txt.
Code for OHM coefficients to use for this surface during dry conditions in winter. Links to SUEWS_OHMCoefficients.txt . Value of integer is arbitrary but must match code specified in column 1 of SUEWS_OHMCoefficients.txt.
Code for OHM coefficients to use for this surface during dry conditions in winter. Links to SUEWS_OHMCoefficients.txt . Value of integer is arbitrary but must match code specified in column 1 of SUEWS_OHMCoefficients.txt.
Code for OHM coefficients to use for this surface during dry conditions in winter. Links to SUEWS_OHMCoefficients.txt . Value of integer is arbitrary but must match code specified in column 1 of SUEWS_OHMCoefficients.txt.
-
OHMCode_WinterWet
¶
-
- Description
-
Code for OHM coefficients to use for this surface during wet conditions in winter, linking to SUEWS_OHMCoefficients.txt.
- Configuration
-
Referencing Table
Requirement
Comment
Code for OHM coefficients to use for this surface during wet conditions in winter. Links to SUEWS_OHMCoefficients.txt . Value of integer is arbitrary but must match code specified in column 1 of SUEWS_OHMCoefficients.txt.
Code for OHM coefficients to use for this surface during wet conditions in winter. Links to SUEWS_OHMCoefficients.txt . Value of integer is arbitrary but must match code specified in column 1 of SUEWS_OHMCoefficients.txt.
Code for OHM coefficients to use for this surface during wet conditions in winter. Links to SUEWS_OHMCoefficients.txt . Value of integer is arbitrary but must match code specified in column 1 of SUEWS_OHMCoefficients.txt.
Code for OHM coefficients to use for this surface during wet conditions in winter. Links to SUEWS_OHMCoefficients.txt . Value of integer is arbitrary but must match code specified in column 1 of SUEWS_OHMCoefficients.txt.
-
OHMThresh_SW
¶
-
- Description
-
Temperature threshold determining whether summer/winter OHM coefficients are applied [°C]
- Configuration
-
Referencing Table
Requirement
Comment
Temperature threshold determining whether summer/winter OHM coefficients are applied [°C] If 5-day running mean air temperature is greater than or equal to this threshold, OHM coefficients for summertime are applied; otherwise coefficients for wintertime are applied.
Temperature threshold determining whether summer/winter OHM coefficients are applied [°C] If 5-day running mean air temperature is greater than or equal to this threshold, OHM coefficients for summertime are applied; otherwise coefficients for wintertime are applied.
Temperature threshold determining whether summer/winter OHM coefficients are applied [°C] If 5-day running mean air temperature is greater than or equal to this threshold, OHM coefficients for summertime are applied; otherwise coefficients for wintertime are applied.
Not actually used for Snow surface as winter wet conditions always assumed.
-
OHMThresh_WD
¶
-
- Description
-
Soil moisture threshold determining whether wet/dry OHM coefficients are applied [-]
- Configuration
-
Referencing Table
Requirement
Comment
Not actually used for building and paved surfaces (as impervious).
Note that OHM coefficients for wet conditions are applied if the surface is wet.
Not actually used for water surface (as no soil surface beneath).
Not actually used for Snow surface as winter wet conditions always assumed.
-
PipeCapacity
¶
-
- Description
-
Storage capacity of pipes [mm]
- Configuration
-
Referencing Table
Requirement
Comment
Storage capacity of pipes [mm] Runoff amounting to less than the value specified here is assumed to be removed by pipes.
-
PopDensDay
¶
-
- Description
-
Daytime population density (i.e. workers, tourists) [people ha-1]
- Configuration
-
Referencing Table
Requirement
Comment
Daytime population density (i.e. workers, tourists) [people ha -1 ] Population density is required if EmissionsMethod = 2 in RunControl.nml . The model will use the average of daytime and night-time population densities, unless only one is provided. If daytime population density is unknown, set to -999.
-
PopDensNight
¶
-
- Description
-
Night-time population density (i.e. residents) [people ha-1]
- Configuration
-
Referencing Table
Requirement
Comment
Night-time population density (i.e. residents) [people ha -1 ] Population density is required if EmissionsMethod = 2 in RunControl.nml . The model will use the average of daytime and night-time population densities, unless only one is provided. If night-time population density is unknown, set to -999.
-
PopProfWD
¶
-
- Description
-
Code for population density profile (weekdays) linking to
Code
of SUEWS_Profiles.txt. - Configuration
-
Referencing Table
Requirement
Comment
Code for population density profile (weekdays).
-
PopProfWE
¶
-
- Description
-
Code for population density profile (weekends) linking to
Code
of SUEWS_Profiles.txt. - Configuration
-
Referencing Table
Requirement
Comment
Code for population density profile (weekends)
-
PorosityMax
¶
-
- Description
-
full leaf-on summertime value Used only for
DecTr
(can affect roughness calculation) - Configuration
-
Referencing Table
Requirement
Comment
full leaf-on summertime value Used only for DecTr (can affect roughness calculation)
-
PorosityMin
¶
-
- Description
-
leaf-off wintertime value Used only for
DecTr
(can affect roughness calculation) - Configuration
-
Referencing Table
Requirement
Comment
leaf-off wintertime value Used only for DecTr (can affect roughness calculation)
-
PrecipLimAlb
¶
-
- Description
-
Limit for hourly precipitation when the ground is fully covered with snow [mm]
- Configuration
-
Referencing Table
Requirement
Comment
Limit for hourly precipitation when the ground is fully covered with snow. Then snow albedo is reset to AlbedoMax [mm]
-
PrecipLimSnow
¶
-
- Description
-
Temperature limit when precipitation falls as snow [°C]
- Configuration
-
Referencing Table
Requirement
Comment
Auer (1974)
-
pres
¶
-
- Description
-
Barometric pressure [kPa]
- Configuration
-
Referencing Table
Requirement
Comment
Barometric pressure [kPa]
-
qe
¶
-
- Description
-
Latent heat flux [W m-2]
- Configuration
-
Referencing Table
Requirement
Comment
Latent heat flux [W m-2]
-
qf
¶
-
- Description
-
Anthropogenic heat flux [W m-2]
- Configuration
-
Referencing Table
Requirement
Comment
Anthropogenic heat flux [W m-2]
-
QF_A_WD
¶
-
- Description
-
Base value for QF on weekdays [W m-2 (Cap ha-1 )-1 ]
- Configuration
-
Referencing Table
Requirement
Comment
Use with
EmissionsMethod
= 2Example values:
0.3081 (Järvi et al., 2011)
0.1 (Järvi et al., 2014)
-
QF_A_WE
¶
-
- Description
-
Base value for QF on weekends [W m-2 (Cap ha-1 )-1]
- Configuration
-
Referencing Table
Requirement
Comment
Use with
EmissionsMethod
= 2Example values:
0.3081 (Järvi et al., 2011)
0.1 (Järvi et al., 2014)
-
QF_B_WD
¶
-
- Description
-
Parameter related to cooling degree days on weekdays [W m-2 K-1 (Cap ha-1 )-1]
- Configuration
-
Referencing Table
Requirement
Comment
Use with
EmissionsMethod
= 2Example values:
0.0099 (Järvi et al., 2011)
0.0099 (Järvi et al., 2014)
-
QF_B_WE
¶
-
- Description
-
Parameter related to cooling degree days on weekends [W m-2 K-1 (Cap ha-1 )-1]
- Configuration
-
Referencing Table
Requirement
Comment
Use with
EmissionsMethod
= 2Example values:
0.0099 (Järvi et al., 2011)
0.0099 (Järvi et al., 2014)
-
QF_C_WD
¶
-
- Description
-
Parameter related to heating degree days on weekdays [W m-2 K-1 (Cap ha-1 )-1]
- Configuration
-
Referencing Table
Requirement
Comment
Use with
EmissionsMethod
= 2Example values:
0.0102 (Järvi et al., 2011)
0.0102 (Järvi et al., 2014)
-
QF_C_WE
¶
-
- Description
-
Parameter related to heating degree days on weekends [W m-2 K-1 (Cap ha-1 )-1]
- Configuration
-
Referencing Table
Requirement
Comment
Example values:
0.0102 (Järvi et al., 2011)
0.0102 (Järvi et al., 2014)
-
q+_gkg
¶
-
- Description
-
specific humidity at the top of CBL [g kg-1]
- Configuration
-
Referencing Table
Requirement
Comment
specific humidity at the top of CBL (g kg-1 )
-
q_gkg
¶
-
- Description
-
specific humidiy in CBL [g kg-1]
- Configuration
-
Referencing Table
Requirement
Comment
specific humidiy in CBL (g kg-1 )
-
qh
¶
-
- Description
-
Sensible heat flux [W m-2]
- Configuration
-
Referencing Table
Requirement
Comment
Sensible heat flux [W m-2]
-
qn
¶
-
- Description
-
Net all-wave radiation [W m-2]
- Configuration
-
Referencing Table
Requirement
Comment
Required if
NetRadiationMethod
= 1.
-
qs
¶
-
- Description
-
Storage heat flux [W m-2]
- Configuration
-
Referencing Table
Requirement
Comment
Storage heat flux [W m-2]
-
RadMeltFactor
¶
-
- Description
-
Hourly radiation melt factor of snow [mm W-1 h-1]
- Configuration
-
Referencing Table
Requirement
Comment
Hourly radiation melt factor of snow [mm W-1 h-1]
-
rain
¶
-
- Description
-
Rainfall [mm]
- Configuration
-
Referencing Table
Requirement
Comment
Rainfall [mm]
-
RH
¶
-
- Description
-
Relative Humidity [%]
- Configuration
-
Referencing Table
Requirement
Comment
Relative Humidity [%]
-
RunoffToWater
¶
-
- Description
-
Fraction of above-ground runoff flowing to water surface during flooding [-]
- Configuration
-
Referencing Table
Requirement
Comment
Fraction of above-ground runoff flowing to water surface during flooding [-] Value must be in the range 0-1. Fraction of above-ground runoff that can flow to the water surface in the case of flooding.
-
S1
¶
-
- Description
-
A parameter related to soil moisture dependence [-]
- Configuration
-
Referencing Table
Requirement
Comment
Related to soil moisture dependence [-] These will change in the future to ensure consistency with soil behaviour
-
S2
¶
-
- Description
-
A parameter related to soil moisture dependence [mm]
- Configuration
-
Referencing Table
Requirement
Comment
Related to soil moisture dependence [mm] These will change in the future to ensure consistency with soil behaviour
-
SatHydraulicCond
¶
-
- Description
-
Hydraulic conductivity for saturated soil [mm s-1]
- Configuration
-
Referencing Table
Requirement
Comment
Hydraulic conductivity for saturated soil [mm s-1]
-
SDDFull
¶
-
- Description
-
The sensesence degree days (SDD) needed to initiate leaf off. [°C]
- Configuration
-
Referencing Table
Requirement
Comment
This should be checked carefully for your study area using modelled LAI from the DailyState output file compared to known behaviour in the study area. See section 2.2 of Järvi et al. (2011) and Appendix A of Järvi et al. (2014) for more details.
Example values:
-450:
EveTr
(Järvi et al., 2011)-450:
DecTr
(Järvi et al., 2011)-450:
Grass
(Järvi et al., 2011)
-
snow
¶
-
- Description
-
Snowfall [mm]
- Configuration
-
Referencing Table
Requirement
Comment
Required if
SnowUse
= 1
-
SnowClearingProfWD
¶
-
- Description
-
Code for snow clearing profile (weekdays) linking to
Code
of SUEWS_Profiles.txt. - Configuration
-
Referencing Table
Requirement
Comment
Code for snow clearing profile (weekdays) Provides the link to column 1 of SUEWS_Profiles.txt. Value of integer is arbitrary but must match code specified in column 1 of SUEWS_Profiles.txt. e.g. 1 means use the characteristics specified in the row of input file SUEWS_Profiles.txt which has 1 in column 1 (Code).
-
SnowClearingProfWE
¶
-
- Description
-
Code for snow clearing profile (weekends) linking to
Code
of SUEWS_Profiles.txt. - Configuration
-
Referencing Table
Requirement
Comment
Code for snow clearing profile (weekends) Provides the link to column 1 of SUEWS_Profiles.txt. Value of integer is arbitrary but must match code specified in column 1 of SUEWS_Profiles.txt. e.g. 1 means use the characteristics specified in the row of input file SUEWS_Profiles.txt which has 1 in column 1 (Code). Providing the same code for
SnowClearingProfWD
andSnowClearingProfWE
would link to the same row in SUEWS_Profiles.txt, i.e. the same profile would be used for weekdays and weekends.
-
SnowCode
¶
-
- Description
-
Code for snow surface characteristics linking to
Code
of SUEWS_Snow.txt - Configuration
-
Referencing Table
Requirement
Comment
Code for snow surface characteristics Provides the link to column 1 of SUEWS_Snow.txt, which contains the attributes describing snow surfaces in this grid for this year. Value of integer is arbitrary but must match code specified in column 1 of SUEWS_Snow.txt.
-
SnowDensMax
¶
-
- Description
-
Maximum snow density [kg m-3]
- Configuration
-
SnowDensMin
¶
-
- Description
-
Fresh snow density [kg m-3]
- Configuration
-
SnowLimPatch
¶
-
- Description
-
Limit for the snow water equivalent when snow cover starts to be patchy [mm]
- Configuration
-
Referencing Table
Requirement
Comment
Limit of snow water equivalent when the surface is fully covered with snow. Not needed if
SnowUse
= 0 in RunControl.nml .Example values:
190: Paved (Järvi et al., 2014)
190: Bldgs (Järvi et al., 2014)
190: BSoil (Järvi et al., 2014)
Limit of snow water equivalent when the surface is fully covered with snow. Not needed if
SnowUse
= 0 in RunControl.nml .Example values:
190: EveTr (Järvi et al., 2014)
190: DecTr (Järvi et al., 2014)
190: Grass (Järvi et al., 2014)
-
SnowLimRemove
¶
-
- Description
-
Limit of the snow water equivalent for snow removal from roads and roofs [mm]
- Configuration
-
Referencing Table
Requirement
Comment
Not needed if
SnowUse
= 0 in RunControl.nml . Not available in this version.Example values [mm]
40:
Paved
(Järvi et al., 2014)100:
Bldgs
(Järvi et al., 2014)
-
SoilDensity
¶
-
- Description
-
Soil density [kg m-3]
- Configuration
-
Referencing Table
Requirement
Comment
Soil density [kg m-3]
-
SoilDepth
¶
-
- Description
-
Depth of soil beneath the surface [mm]
- Configuration
-
Referencing Table
Requirement
Comment
Depth of sub-surface soil store [mm] i.e. the depth of soil beneath the surface
-
SoilStoreCap
¶
-
- Description
-
Limit value for
SoilDepth
[mm] - Configuration
-
Referencing Table
Requirement
Comment
SoilStoreCap must not be greater than SoilDepth.
-
SoilTypeCode
¶
-
- Description
-
Code for soil characteristics below this surface linking to
Code
of SUEWS_Soil.txt - Configuration
-
Referencing Table
Requirement
Comment
Code for soil characteristics below this surface Provides the link to column 1 of SUEWS_Soil.txt, which contains the attributes describing sub-surface soil for this surface type. Value of integer is arbitrary but must match code specified in column 1 of SUEWS_Soil.txt.
Code for soil characteristics below this surface Provides the link to column 1 of SUEWS_Soil.txt, which contains the attributes describing sub-surface soil for this surface type. Value of integer is arbitrary but must match code specified in column 1 of SUEWS_Soil.txt.
-
StartDLS
¶
-
- Description
-
Start of the day light savings [DOY]
- Configuration
-
Referencing Table
Requirement
Comment
Start of the day light savings [DOY] See Day Light Savings (DLS).
-
StateLimit
¶
-
- Description
-
Upper limit to the surface state. [mm]
Currently only used for the water surface. Set to a large value (e.g. 20000 mm = 20 m) if the water body is substantial (lake, river, etc) or a small value (e.g. 10 mm) if water bodies are very shallow (e.g. fountains). WaterDepth (column 9) must not exceed this value.
- Configuration
-
Referencing Table
Requirement
Comment
Currently only used for the water surface
Currently only used for the water surface
Surface state cannot exceed this value. Set to a large value (e.g. 20000 mm = 20 m) if the water body is substantial (lake, river, etc) or a small value (e.g. 10 mm) if water bodies are very shallow (e.g. fountains). WaterDepth (column 9) must not exceed this value.
-
StorageMax
¶
-
- Description
-
Maximum water storage capacity for upper surfaces (i.e. canopy)
- Configuration
-
Referencing Table
Requirement
Comment
Maximum water storage capacity for upper surfaces (i.e. canopy) Min and max values are to account for seasonal variation (e.g. leaf-on/leaf-off differences for vegetated surfaces). Not currently used for non-vegetated surfaces - set the same as
StorageMin
.Example values:
Maximum water storage capacity for upper surfaces (i.e. canopy) Min/max values are to account for seasonal variation (e.g. leaf-off/leaf-on differences for vegetated surfaces) Only used for
DecTr
surfaces - setEveTr
andGrass
values the same asStorageMin
.Example values:
1.3:
EveTr
(Breuer et al., 2003)0.8:
DecTr
(Breuer et al., 2003)1.9:
Grass
(Breuer et al., 2003)
Maximum water storage capacity for upper surfaces (i.e. canopy) Min and max values are to account for seasonal variation - not used for water surfaces so set same as
StorageMin
.
-
StorageMin
¶
-
- Description
-
Minimum water storage capacity for upper surfaces (i.e. canopy).
- Configuration
-
Referencing Table
Requirement
Comment
Minimum water storage capacity for upper surfaces (i.e. canopy). Min/max values are to account for seasonal variation (e.g. leaf-on/leaf-off differences for vegetated surfaces). Not currently used for non-vegetated surfaces - set the same as
StorageMax
.Example values:
Minimum water storage capacity for upper surfaces (i.e. canopy). Min/max values are to account for seasonal variation (e.g. leaf-off/leaf-on differences for vegetated surfaces).
Example values:
1.3
EveTr
(Breuer et al., 2003)0.3
DecTr
(Breuer et al., 2003)1.9
Grass
(Breuer et al., 2003)
Minimum water storage capacity for upper surfaces (i.e. canopy). Min/max values are to account for seasonal variation - not used for water surfaces.
Example values:
-0.5
Water
-
SurfaceArea
¶
-
- Description
-
Area of the grid [ha].
- Configuration
-
Referencing Table
Requirement
Comment
Area of the grid [ha].
-
Surf_k1
¶
-
- Description
-
Thermal conductivity of the first layer [W m-1 K-1]
- Configuration
-
Referencing Table
Requirement
Comment
Thermal conductivity of the first layer [W m-1 K-1]
-
Surf_k2
¶
-
- Description
-
Thermal conductivity of the second layer [W m-1 K-1]
- Configuration
-
Referencing Table
Requirement
Comment
Thermal conductivity of the second layer [W m-1 K-1]
-
Surf_k3
¶
-
- Description
-
Thermal conductivity of the third layer[W m-1 K-1]
- Configuration
-
Referencing Table
Requirement
Comment
Thermal conductivity of the third layer[W m-1 K-1]
-
Surf_k4
¶
-
- Description
-
Thermal conductivity of the fourth layer[W m-1 K-1]
- Configuration
-
Referencing Table
Requirement
Comment
Thermal conductivity of the fourth layer[W m-1 K-1]
-
Surf_k5
¶
-
- Description
-
Thermal conductivity of the fifth layer [W m-1 K-1]
- Configuration
-
Referencing Table
Requirement
Comment
Thermal conductivity of the fifth layer [W m-1 K-1]
-
Surf_rhoCp1
¶
-
- Description
-
Volumetric heat capacity of the first layer [J m-3 K-1]
- Configuration
-
Referencing Table
Requirement
Comment
Volumetric heat capacity of the first layer [J m-3 K-1]
-
Surf_rhoCp2
¶
-
- Description
-
Volumetric heat capacity of the second layer [J m-3 K-1]
- Configuration
-
Referencing Table
Requirement
Comment
Volumetric heat capacity of the second layer [J m-3 K-1]
-
Surf_rhoCp3
¶
-
- Description
-
Volumetric heat capacity of the third layer[J m-3 K-1]
- Configuration
-
Referencing Table
Requirement
Comment
Volumetric heat capacity of the third layer[J m-3 K-1]
-
Surf_rhoCp4
¶
-
- Description
-
Volumetric heat capacity of the fourth layer [J m-3 K-1]
- Configuration
-
Referencing Table
Requirement
Comment
Volumetric heat capacity of the fourth layer [J m-3 K-1]
-
Surf_rhoCp5
¶
-
- Description
-
Volumetric heat capacity of the fifth layer [J m-3 K-1]
- Configuration
-
Referencing Table
Requirement
Comment
Volumetric heat capacity of the fifth layer [J m-3 K-1]
-
Surf_thick1
¶
-
- Description
-
Thickness of the first layer [m] for roofs (building surfaces) and ground (all other surfaces)
- Configuration
-
Referencing Table
Requirement
Comment
Thickness of the first layer [m] for roofs (building surfaces) and ground (all other surfaces)
-
Surf_thick2
¶
-
- Description
-
Thickness of the second layer [m] (if no second layer, set to -999.)
- Configuration
-
Referencing Table
Requirement
Comment
Thickness of the second layer [m] (if no second layer, set to -999.)
-
Surf_thick3
¶
-
- Description
-
Thickness of the third layer [m] (if no third layer, set to -999.)
- Configuration
-
Referencing Table
Requirement
Comment
Thickness of the third layer [m] (if no third layer, set to -999.)
-
Surf_thick4
¶
-
- Description
-
Thickness of the fourth layer [m] (if no fourth layer, set to -999.)
- Configuration
-
Referencing Table
Requirement
Comment
Thickness of the fourth layer [m] (if no fourth layer, set to -999.)
-
Surf_thick5
¶
-
- Description
-
Thickness of the fifth layer [m] (if no fifth layer, set to -999.)
- Configuration
-
Referencing Table
Requirement
Comment
Thickness of the fifth layer [m] (if no fifth layer, set to -999.)
-
Tair
¶
-
- Description
-
Air temperature [°C]
- Configuration
-
Referencing Table
Requirement
Comment
Air temperature [°C]
-
tau_a
¶
-
- Description
-
Time constant for snow albedo aging in cold snow [-]
- Configuration
-
Referencing Table
Requirement
Comment
Time constant for snow albedo aging in cold snow [-]
-
tau_f
¶
-
- Description
-
Time constant for snow albedo aging in melting snow [-]
- Configuration
-
Referencing Table
Requirement
Comment
Time constant for snow albedo aging in melting snow [-]
-
tau_r
¶
-
- Description
-
Time constant for snow density ageing [-]
- Configuration
-
Referencing Table
Requirement
Comment
Time constant for snow density ageing [-]
-
TCritic_Heating_WD
¶
-
- Description
-
Critical heating temperature on weekdays [°C]
- Configuration
-
Referencing Table
Requirement
Comment
Use with
EmissionsMethod
= 1
-
TCritic_Heating_WE
¶
-
- Description
-
Critical heating temperature on weekends [°C]
- Configuration
-
Referencing Table
Requirement
Comment
Use with
EmissionsMethod
= 1
-
TCritic_Cooling_WD
¶
-
- Description
-
Critical cooling temperature on weekdays [°C]
- Configuration
-
Referencing Table
Requirement
Comment
Use with
EmissionsMethod
= 1
-
TCritic_Cooling_WE
¶
-
- Description
-
Critical cooling temperature on weekends [°C]
- Configuration
-
Referencing Table
Requirement
Comment
Use with
EmissionsMethod
= 1
-
TempMeltFactor
¶
-
- Description
-
Hourly temperature melt factor of snow [mm K-1 h-1]
- Configuration
-
Referencing Table
Requirement
Comment
Hourly temperature melt factor of snow [mm K-1 h-1] (In previous model version, this parameter was 0.12)
-
TH
¶
-
- Description
-
Upper air temperature limit [°C]
- Configuration
-
Referencing Table
Requirement
Comment
Upper air temperature limit [°C]
-
Theta+_K
¶
-
- Description
-
potential temperature at the top of CBL [K]
- Configuration
-
Referencing Table
Requirement
Comment
potential temperature at the top of CBL (K)
-
Theta_K
¶
-
- Description
-
potential temperature in CBL [K]
- Configuration
-
Referencing Table
Requirement
Comment
potential temperature in CBL (K)
-
Tiair
¶
-
- Description
-
Indoor air temperature [ËšC]
- Configuration
-
Referencing Table
Requirement
Comment
Indoor air temperature [ËšC]
-
Timezone
¶
-
- Description
-
Time zone [h] for site relative to UTC (east is positive). This should be set according to the times given in the meteorological forcing file(s).
- Configuration
-
Referencing Table
Requirement
Comment
Time zone [h] for site relative to UTC (east is positive). This should be set according to the times given in the meteorological forcing file(s).
-
TL
¶
-
- Description
-
Lower air temperature limit [°C]
- Configuration
-
Referencing Table
Requirement
Comment
Lower air temperature limit [°C]
-
ToBldgs
¶
-
- Description
-
Fraction of water going to
Bldgs
- Configuration
-
Referencing Table
Requirement
Comment
Fraction of water going to
Bldgs
-
ToBSoil
¶
-
- Description
-
Fraction of water going to
BSoil
- Configuration
-
Referencing Table
Requirement
Comment
Fraction of water going to
BSoil
-
ToDecTr
¶
-
- Description
-
Fraction of water going to
DecTr
- Configuration
-
Referencing Table
Requirement
Comment
Fraction of water going to
DecTr
-
ToEveTr
¶
-
ToGrass
¶
-
ToPaved
¶
-
ToRunoff
¶
-
ToSoilStore
¶
-
ToWater
¶
-
TraffProfWD
¶
-
- Description
-
Code for traffic activity profile (weekdays) linking to
Code
of SUEWS_Profiles.txt. Not used in v2018a. - Configuration
-
Referencing Table
Requirement
Comment
Weekday building energy use [W m-2] Can be used for CO2 flux calculation.
-
TraffProfWE
¶
-
- Description
-
Code for traffic activity profile (weekends) linking to
Code
of SUEWS_Profiles.txt. Not used in v2018a. - Configuration
-
Referencing Table
Requirement
Comment
Weekday building energy use [W m-2] Can be used for CO2 flux calculation.
-
TrafficUnits
¶
-
- Description
-
Units for the traffic rate for the study area. Not used in v2018a.
- Configuration
-
Referencing Table
Requirement
Comment
Weekday building energy use [W m-2] Can be used for CO2 flux calculation.
-
TrafficRate_WD
¶
-
- Description
-
Weekday traffic rate [veh km m-2 s-1] Can be used for CO2 flux calculation - not used in v2018a.
- Configuration
-
Referencing Table
Requirement
Comment
Weekday traffic rate [veh km m-2 s-1] Can be used for CO2 flux calculation.
-
TrafficRate_WE
¶
-
- Description
-
Weekend traffic rate [veh km m-2 s-1] Can be used for CO2 flux calculation - not used in v2018a.
- Configuration
-
Referencing Table
Requirement
Comment
Weekend traffic rate [veh km m-2 s-1] Can be used for CO2 flux calculation.
-
Troad
¶
-
- Description
-
Ground surface temperature [ËšC] (used when
TsurfChoice
= 1 or 2) - Configuration
-
Referencing Table
Requirement
Comment
Ground surface temperature [ËšC] (used when
TsurfChoice
= 1 or 2)
-
Troof
¶
-
- Description
-
Roof surface temperature [ËšC] (used when
TsurfChoice
= 1 or 2) - Configuration
-
Referencing Table
Requirement
Comment
Roof surface temperature [ËšC] (used when
TsurfChoice
= 1 or 2)
-
Tsurf
¶
-
- Description
-
Bulk surface temperature [ËšC] (used when
TsurfChoice
= 0) - Configuration
-
Referencing Table
Requirement
Comment
Bulk surface temperature [ËšC] (used when TsurfCoice = 0)
-
Twall
¶
-
- Description
-
Wall surface temperature [ËšC] (used when
TsurfChoice
= 1) - Configuration
-
Referencing Table
Requirement
Comment
Wall surface temperature [ËšC] (used when
TsurfChoice
= 1)
-
Twall_e
¶
-
- Description
-
East-facing wall surface temperature [ËšC] (used when
TsurfChoice
= 2) - Configuration
-
Referencing Table
Requirement
Comment
East-facing wall surface temperature [ËšC] (used when
TsurfChoice
= 2)
-
Twall_n
¶
-
- Description
-
North-facing wall surface temperature [ËšC] (used when
TsurfChoice
= 2) - Configuration
-
Referencing Table
Requirement
Comment
North-facing wall surface temperature [ËšC] (used when
TsurfChoice
= 2)
-
Twall_s
¶
-
- Description
-
South-facing wall surface temperature [ËšC] (used when
TsurfChoice
= 2) - Configuration
-
Referencing Table
Requirement
Comment
South-facing wall surface temperature [ËšC] (used when
TsurfChoice
= 2)
-
Twall_w
¶
-
- Description
-
West-facing wall surface temperature [ËšC] (used when
TsurfChoice
= 2) - Configuration
-
Referencing Table
Requirement
Comment
West-facing wall surface temperature [ËšC] (used when
TsurfChoice
= 2)
-
U
¶
-
- Description
-
Wind speed. [m s-1. ]Height of the wind speed measurement (
z
) is needed in SUEWS_SiteSelect.txt . - Configuration
-
Referencing Table
Requirement
Comment
Height of the wind speed measurement (z) is needed in SUEWS_SiteSelect.txt.
-
Wall_k1
¶
-
- Description
-
Thermal conductivity of the first layer [W m-1 K-1]
- Configuration
-
Referencing Table
Requirement
Comment
Thermal conductivity of the first layer [W m-1 K-1]
-
Wall_k2
¶
-
- Description
-
Thermal conductivity of the second layer [W m-1 K-1]
- Configuration
-
Referencing Table
Requirement
Comment
Thermal conductivity of the second layer [W m-1 K-1]
-
Wall_k3
¶
-
- Description
-
Thermal conductivity of the third layer [W m-1 K-1]
- Configuration
-
Referencing Table
Requirement
Comment
Thermal conductivity of the third layer [W m-1 K-1]
-
Wall_k4
¶
-
- Description
-
Thermal conductivity of the fourth layer[W m-1 K-1]
- Configuration
-
Referencing Table
Requirement
Comment
Thermal conductivity of the fourth layer[W m-1 K-1]
-
Wall_k5
¶
-
- Description
-
Thermal conductivity of the fifth layer[W m-1 K-1]
- Configuration
-
Referencing Table
Requirement
Comment
Thermal conductivity of the fifth layer[W m-1 K-1]
-
Wall_rhoCp1
¶
-
- Description
-
Volumetric heat capacity of the first layer [J m-3 K-1]
- Configuration
-
Referencing Table
Requirement
Comment
Volumetric heat capacity of the first layer [J m-3 K-1]
-
Wall_rhoCp2
¶
-
- Description
-
Volumetric heat capacity of the second layer [J m-3 K-1]
- Configuration
-
Referencing Table
Requirement
Comment
Volumetric heat capacity of the second layer [J m-3 K-1]
-
Wall_rhoCp3
¶
-
- Description
-
Volumetric heat capacity of the third layer [J m-3 K-1]
- Configuration
-
Referencing Table
Requirement
Comment
Volumetric heat capacity of the third layer [J m-3 K-1]
-
Wall_rhoCp4
¶
-
- Description
-
Volumetric heat capacity of the fourth layer [J m-3 K-1]
- Configuration
-
Referencing Table
Requirement
Comment
Volumetric heat capacity of the fourth layer [J m-3 K-1]
-
Wall_rhoCp5
¶
-
- Description
-
Volumetric heat capacity of the fifth layer [J m-3 K-1]
- Configuration
-
Referencing Table
Requirement
Comment
Volumetric heat capacity of the fifth layer [J m-3 K-1]
-
Wall_thick1
¶
-
- Description
-
Thickness of the first layer [m] for building surfaces only; set to -999 for all other surfaces
- Configuration
-
Referencing Table
Requirement
Comment
Thickness of the first layer [m] for building surfaces only; set to -999 for all other surfaces
-
Wall_thick2
¶
-
- Description
-
Thickness of the second layer [m] (if no second layer, set to -999.)
- Configuration
-
Referencing Table
Requirement
Comment
Thickness of the second layer [m] (if no second layer, set to -999.)
-
Wall_thick3
¶
-
- Description
-
Thickness of the third layer [m] (if no third layer, set to -999.)
- Configuration
-
Referencing Table
Requirement
Comment
Thickness of the third layer [m] (if no third layer, set to -999.)
-
Wall_thick4
¶
-
- Description
-
Thickness of the fourth layer [m] (if no fourth layer, set to -999.)
- Configuration
-
Referencing Table
Requirement
Comment
Thickness of the fourth layer [m] (if no fourth layer, set to -999.)
-
Wall_thick5
¶
-
- Description
-
Thickness of the fifth layer [m] (if no fifth layer, set to -999.)
- Configuration
-
Referencing Table
Requirement
Comment
Thickness of the fifth layer [m] (if no fifth layer, set to -999.)
-
WaterDepth
¶
-
- Description
-
Water depth [mm].
- Configuration
-
Referencing Table
Requirement
Comment
Set to a large value (e.g. 20000 mm = 20 m) if the water body is substantial (lake, river, etc) or a small value (e.g. 10 mm) if water bodies are very shallow (e.g. fountains). This value must not exceed StateLimit (column 8).
-
WaterUseProfAutoWD
¶
-
- Description
-
Code for water use profile (automatic irrigation, weekdays) linking to
Code
of SUEWS_Profiles.txt. Value of integer is arbitrary but must match code specified inCode
of SUEWS_Profiles.txt. - Configuration
-
Referencing Table
Requirement
Comment
Code for water use profile (automatic irrigation, weekdays) Provides the link to column 1 of SUEWS_Profiles.txt. Value of integer is arbitrary but must match code specified in column 1 of SUEWS_Profiles.txt.
-
WaterUseProfAutoWE
¶
-
- Description
-
Code for water use profile (automatic irrigation, weekends) linking to
Code
of SUEWS_Profiles.txt. Value of integer is arbitrary but must match code specified inCode
of SUEWS_Profiles.txt. - Configuration
-
Referencing Table
Requirement
Comment
Code for water use profile (automatic irrigation, weekends) Provides the link to column 1 of SUEWS_Profiles.txt. Value of integer is arbitrary but must match code specified in column 1 of SUEWS_Profiles.txt.
-
WaterUseProfManuWD
¶
-
- Description
-
Code for water use profile (manual irrigation, weekdays) linking to
Code
of SUEWS_Profiles.txt. - Configuration
-
Referencing Table
Requirement
Comment
Code for water use profile (manual irrigation, weekdays) Provides the link to column 1 of SUEWS_Profiles.txt. Value of integer is arbitrary but must match code specified in column 1 of SUEWS_Profiles.txt.
-
WaterUseProfManuWE
¶
-
- Description
-
Code for water use profile (manual irrigation, weekends) linking to
Code
of SUEWS_Profiles.txt. - Configuration
-
Referencing Table
Requirement
Comment
Code for water use profile (manual irrigation, weekends) Provides the link to column 1 of SUEWS_Profiles.txt. Value of integer is arbitrary but must match code specified in column 1 of SUEWS_Profiles.txt.
-
wdir
¶
-
- Description
-
Wind direction [deg].
- Configuration
-
Referencing Table
Requirement
Comment
Not available in this version.
-
WetThreshold
¶
-
- Description
-
Depth of water which determines whether evaporation occurs from a partially wet or completely wet surface [mm].
- Configuration
-
Referencing Table
Requirement
Comment
Depth of water which determines whether evaporation occurs from a partially wet or completely wet surface.
Example values:
0.6 Paved
0.6 Bldgs
-
BSoil
Depth of water which determines whether evaporation occurs from a partially wet or completely wet surface.
Example values:
1.8 EveTr
-
DecTr
-
Grass
Depth of water which determines whether evaporation occurs from a partially wet or completely wet surface.
Example values:
0.5 Water
-
WithinGridBldgsCode
¶
-
- Description
-
Code that links to the fraction of water that flows from
Bldgs
surfaces to surfaces in columns 2-10 of SUEWS_WithinGridWaterDist.txt - Configuration
-
Referencing Table
Requirement
Comment
Code that links to the fraction of water that flows from Bldgs surfaces to surfaces in columns 2-10 of SUEWS_WithinGridWaterDist.txt. Value of integer is arbitrary but must match code specified in column 1 of SUEWS_WithinGridWaterDist.txt.
-
WithinGridBSoilCode
¶
-
- Description
-
Code that links to the fraction of water that flows from
BSoil
surfaces to surfaces in columns 2-10 of SUEWS_WithinGridWaterDist.txt. - Configuration
-
Referencing Table
Requirement
Comment
Code that links to the fraction of water that flows from BSoil surfaces to surfaces in columns 2-10 of SUEWS_WithinGridWaterDist.txt. Value of integer is arbitrary but must match code specified in column 1 of SUEWS_WithinGridWaterDist.txt.
-
WithinGridDecTrCode
¶
-
- Description
-
Code that links to the fraction of water that flows from
DecTr
surfaces to surfaces in columns 2-10 of SUEWS_WithinGridWaterDist.txt. - Configuration
-
Referencing Table
Requirement
Comment
Code that links to the fraction of water that flows from DecTr surfaces to surfaces in columns 2-10 of SUEWS_WithinGridWaterDist.txt. Value of integer is arbitrary but must match code specified in column 1 of SUEWS_WithinGridWaterDist.txt.
-
WithinGridEveTrCode
¶
-
- Description
-
Code that links to the fraction of water that flows from
EveTr
surfaces to surfaces in columns 2-10 of SUEWS_WithinGridWaterDist.txt. - Configuration
-
Referencing Table
Requirement
Comment
Code that links to the fraction of water that flows from EveTr surfaces to surfaces in columns 2-10 of SUEWS_WithinGridWaterDist.txt. Value of integer is arbitrary but must match code specified in column 1 of SUEWS_WithinGridWaterDist.txt.
-
WithinGridGrassCode
¶
-
- Description
-
Code that links to the fraction of water that flows from
Grass
surfaces to surfaces in columns 2-10 of SUEWS_WithinGridWaterDist.txt. - Configuration
-
Referencing Table
Requirement
Comment
Code that links to the fraction of water that flows from Grass surfaces to surfaces in columns 2-10 of SUEWS_WithinGridWaterDist.txt. Value of integer is arbitrary but must match code specified in column 1 of SUEWS_WithinGridWaterDist.txt.
-
WithinGridPavedCode
¶
-
- Description
-
Code that links to the fraction of water that flows from
Paved
surfaces to surfaces in columns 2-10 of SUEWS_WithinGridWaterDist.txt. - Configuration
-
Referencing Table
Requirement
Comment
Code that links to the fraction of water that flows from Paved surfaces to surfaces in columns 2-10 of SUEWS_WithinGridWaterDist.txt . Value of integer is arbitrary but must match code specified in column 1 of SUEWS_WithinGridWaterDist.txt.
-
WithinGridWaterCode
¶
-
- Description
-
Code that links to the fraction of water that flows from Water surfaces to surfaces in columns 2-10 of SUEWS_WithinGridWaterDist.txt.
- Configuration
-
Referencing Table
Requirement
Comment
Code that links to the fraction of water that flows from Water surfaces to surfaces in columns 2-10 of SUEWS_WithinGridWaterDist.txt. Value of integer is arbitrary but must match code specified in column 1 of SUEWS_WithinGridWaterDist.txt.
-
Wuh
¶
-
- Description
-
External water use [m3]
- Configuration
-
Referencing Table
Requirement
Comment
External water use [ m3]
-
xsmd
¶
-
- Description
-
Observed soil moisture; can be provided either as volumetric ([m3 m-3] when
SMDMethod
= 1) or gravimetric quantity ([kg kg-1] whenSMDMethod
= 2). This should be used in conjunction with other soil properties in SUEWS_Soil.txt. - Configuration
-
Referencing Table
Requirement
Comment
Observed soil moisture [ m3 m-3 or kg kg-1]
-
Year
¶
-
- Description
-
Year [YYYY]
- Configuration
-
Referencing Table
Requirement
Comment
Year [YYYY] Years must be continuous. If running multiple years, ensure the rows in SUEWS_SiteSelect.txt are arranged so that all grids for a particular year appear on consecutive lines (rather than grouping all years together for a particular grid).
-
z
¶
-
- Description
-
Measurement height [m] for all atmospheric forcing variables set in SSss_YYYY_data_tt.txt.
- Configuration
-
Referencing Table
Requirement
Comment
z must be greater than the displacement height. Forcing data should be representative of the local-scale, i.e. above the height of the roughness elements.
-
z0
¶
-
- Description
-
Roughness length for momentum [m]
- Configuration
-
Referencing Table
Requirement
Comment
Value supplied here is used if
RoughLenMomMethod
= 1 in RunControl.nml ; otherwise set to ‘-999’ and a value will be calculated by the model (RoughLenMomMethod
= 2, 3).
-
zd
¶
-
- Description
-
Zero-plane displacement [m]
- Configuration
-
Referencing Table
Requirement
Comment
Value supplied here is used if
RoughLenMomMethod
= 1 in RunControl.nml ; otherwise set to-999
and a value will be calculated by the model (RoughLenMomMethod
= 2, 3).
-
zi0
¶
-
- Description
-
initial convective boundary layer height (m)
- Configuration
-
Referencing Table
Requirement
Comment
initial convective boundary layer height [m]