Tip
Need help? Please let us know in the UMEP Community.
Please report issues with the manual on the GitHub Issues.
Please cite SUEWS with proper information from our Zenodo page.
6.1.3.4.2. df_forcing
variables#
Note
Data structure of df_forcing
is explained here.
- RH#
- Description
Relative Humidity [%] (measurement height (
z
) is needed in SUEWS_SiteSelect.txt)
- Tair#
- Description
Air temperature [°C] (measurement height (
z
) is needed in SUEWS_SiteSelect.txt)
- U#
- Description
Wind speed [m s-1] (measurement height (
z
) is needed in SUEWS_SiteSelect.txt)
- Wuh#
- Description
External water use [m3]
- fcld#
- Description
Cloud fraction [tenths]
- id#
- Description
Day of year [DOY]
- imin#
- Description
Minute [M]
- isec#
- Description
Second [S]
- it#
- Description
Hour [H]
- iy#
- Description
Year [YYYY]
- kdiff#
- Description
Diffuse radiation [W m-2] Recommended in this version. if
SOLWEIGUse
= 1
- kdir#
- Description
Direct radiation [W m-2] Recommended in this version. if
SOLWEIGUse
= 1
- kdown#
- Description
Incoming shortwave radiation [W m-2] Must be > 0 W m-2.
- lai#
- Description
Observed leaf area index [m-2 m-2]
- ldown#
- Description
Incoming longwave radiation [W m-2]
- pres#
- Description
Barometric pressure [kPa] (measurement height (
z
) is needed in SUEWS_SiteSelect.txt)
- qe#
- Description
Latent heat flux [W m-2]
- qf#
- Description
Anthropogenic heat flux [W m-2]
- qh#
- Description
Sensible heat flux [W m-2]
- qn#
- Description
Net all-wave radiation [W m-2] (Required if
NetRadiationMethod
= 0.)
- qs#
- Description
Storage heat flux [W m-2]
- rain#
- Description
Rainfall [mm] (measurement height (
z
) is needed in SUEWS_SiteSelect.txt)
- wdir#
- Description
Wind direction [°] Not available in this version.
- xsmd#
- Description
Observed soil moisture [m3 m-3] or [kg kg-1]