Note

Please report issues with the manual on the GitHub page.

4.6.2.1. ESTMinput

TsurfChoice
Requirement:

Required

Description:

Source of surface temperature data used.

Configuration:
Value Comments
0 Tsurf in SSss_YYYY_ESTM_Ts_data_tt.txt used for all surface elements.
1 Input surface temperature are different for ground, roof and wall.
2 Wall surface temperature is different for four directions.
evolveTibld
Requirement:

Required

Description:

Source of internal building temperature (Tibld)

Configuration:
Value Comments
0 Tiair in SSss_YYYY_ESTM_Ts_data_tt.txt used.
1 Tibld calculated considering the effect of anthropogenic heat from HVAC
2 Tibld calculated without considering the influence of HVAC.
IbldCHmod
Requirement:

Required

Description:

Method to calculate internal convective heat exchange coefficients (CH) for internal building, wall and roof if evolveTibld is 1 or 2.

Configuration:
Value Comments
0 CHs are read from SUEWS_ESTMcoefficients.txt.
1 CHs are calculated based on ASHRAE (2001)
2 CHs are calculated based on Awbi (1998).
LBC_soil
Requirement:Required
Description:Soil temperature at lowest boundary condition [˚C]
Configuration:to fill
Theat_fix
Requirement:Required
Description:Ideal internal building temperature [˚C]
Configuration:to fill
Theat_off
Requirement:Required
Description:Temperature at which heat control is turned off (used when evolveTibld=1) [˚C]
Configuration:to fill
Theat_on
Requirement:Required
Description:Temperature at which heat control is turned on (used when evolveTibld =1) [˚C]
Configuration:to fill